{"product_id":"honeywell-900cp1-0100-controledge-hc900-control-processor-module","title":"Honeywell 900CP1-0100 ControlEdge HC900 Control Processor Module","description":"\u003ch2\u003eHoneywell 900CP1-0100 ControlEdge HC900 Control Processor Module\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900CP1-0100\u003c\/strong\u003e is the \u003cstrong\u003eControl Processor Module (CPM)\u003c\/strong\u003e at the heart of the \u003cstrong\u003eControlEdge HC900\u003c\/strong\u003e programmable logic controller system. It features a \u003cstrong\u003edual-core ARM Cortex-A9 32-bit processor\u003c\/strong\u003e running at \u003cstrong\u003e667 MHz\u003c\/strong\u003e with \u003cstrong\u003e4 GB dynamic RAM\u003c\/strong\u003e, delivering robust real-time control performance for process automation and discrete manufacturing applications. The module supports native controller redundancy, multiple industrial Ethernet protocols, and tight integration with Honeywell Experion PKS and third-party SCADA systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Honeywell ControlEdge HC900\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Control Processor Module (CPM)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Dual Core ARM Cortex-A9 32-bit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClock Speed:\u003c\/strong\u003e 667 MHz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 4 GB Dynamic RAM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.75 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgramming Environment:\u003c\/strong\u003e ControlEdge Builder (IEC 61131-3 compliant)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative Redundancy:\u003c\/strong\u003e Supported (controller redundancy)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swap Support:\u003c\/strong\u003e Removal and Insertion Under Power (RIUP) for CPM and I\/O modules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, cULus, ATEX (zone 2), IECEx, ISASecure EDSA Level 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommunication Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP:\u003c\/strong\u003e Built-in server and client with ODVA certification; supports DLR (Device Level Ring)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFINET:\u003c\/strong\u003e Built-in PROFINET IO Controller with DLR support\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModbus TCP:\u003c\/strong\u003e Server and client functionality\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOPC UA:\u003c\/strong\u003e Server and client for HMI and SCADA integration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMQTT:\u003c\/strong\u003e With Sparkplug B and DNS function for remote monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNP3:\u003c\/strong\u003e Master and outstation support\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCDA Protocol:\u003c\/strong\u003e For Experion PKS and PlantCruise\/LX integration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60870-5-104:\u003c\/strong\u003e Outstation support\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFTE Support:\u003c\/strong\u003e Fault Tolerant Ethernet network compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePhysical \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Plugs into ControlEdge HC900 I\/O rack (occupies processor slot)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Compliant with IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e Compliant with IEC 60068-2-27\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCyber Security:\u003c\/strong\u003e ISASecure EDSA Level 2 certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Racks:\u003c\/strong\u003e Honeywell ControlEdge HC900 I\/O racks (1-slot, 4-slot, 8-slot, 12-slot configurations)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Power Supplies:\u003c\/strong\u003e 900P01-0201 (120\/240VAC), 900P24-0501 (24VDC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible I\/O Modules:\u003c\/strong\u003e All ControlEdge 900 series digital, analog, universal, and specialty I\/O modules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Expansion:\u003c\/strong\u003e 900SP1-0200 \/ 900SP1-0300 Expansion Processor Modules for distributed I\/O\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Software:\u003c\/strong\u003e ControlEdge Builder engineering station\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Preparation:\u003c\/strong\u003e Mount the ControlEdge HC900 rack on a 35 mm DIN rail in a properly ventilated enclosure. Ensure adequate clearance for heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Installation:\u003c\/strong\u003e Install the power supply module in the designated rack slot before inserting the CPM.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCPM Insertion:\u003c\/strong\u003e Align the 900CP1-0100 with the processor slot (typically leftmost slot) and press firmly until the locking mechanism engages. For redundant configurations, install the secondary CPM in the adjacent slot.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect shielded Cat5e or Cat6 cables to the RJ45 Ethernet ports. Configure IP addresses via ControlEdge Builder or DHCP as required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower On \u0026amp; Commissioning:\u003c\/strong\u003e Apply rack power. Verify status LEDs indicate normal operation. Launch ControlEdge Builder to download the control strategy and establish communication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e If deploying redundant CPMs, enable redundancy in ControlEdge Builder and verify automatic failover functionality during commissioning tests.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController Redundancy:\u003c\/strong\u003e For mission-critical processes, deploy two 900CP1-0100 modules in a redundant pair. The HC900 platform supports seamless bumpless transfer between primary and backup processors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory \u0026amp; Performance:\u003c\/strong\u003e With 4 GB RAM and a 667 MHz dual-core processor, the 900CP1-0100 handles large control strategies with extensive I\/O counts. Verify your application memory requirements in ControlEdge Builder.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtocol Requirements:\u003c\/strong\u003e Confirm your SCADA, HMI, and field device protocols are supported. The 900CP1-0100 offers native EtherNet\/IP, PROFINET, Modbus TCP, OPC UA, and MQTT.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e The -40°C to +70°C rating suits both indoor and harsh outdoor installations. For extreme environments, verify enclosure heating or cooling requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpansion Planning:\u003c\/strong\u003e For I\/O racks remote from the main controller, add 900SP1 expansion processor modules and connect via industrial Ethernet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the difference between 900CP1-0100 and 900CP1-0200?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003e900CP1-0100\u003c\/strong\u003e is an earlier revision of the Control Processor Module. The \u003cstrong\u003e900CP1-0200\u003c\/strong\u003e represents a later hardware revision with updated firmware features. Both occupy the same processor slot and support identical I\/O and communication architectures. Verify software compatibility with your ControlEdge Builder version before selecting.\u003c\/p\u003e\n\n\u003ch4\u003eDoes the 900CP1-0100 support controller redundancy?\u003c\/h4\u003e\n\u003cp\u003eYes. The ControlEdge HC900 platform supports \u003cstrong\u003enative controller redundancy\u003c\/strong\u003e using dual CPMs. Install two 900CP1-0100 modules in the redundant processor slots and configure via ControlEdge Builder for automatic failover.\u003c\/p\u003e\n\n\u003ch4\u003eWhat programming languages are supported?\u003c\/h4\u003e\n\u003cp\u003eThe module is programmed via \u003cstrong\u003eControlEdge Builder\u003c\/strong\u003e using \u003cstrong\u003eIEC 61131-3\u003c\/strong\u003e languages including Ladder Diagram (LD), Function Block Diagram (FBD), Structured Text (ST), Instruction List (IL), and Sequential Function\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53974752559288,"sku":"900CP1-0100","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900CP1-0100_2_07265f6d-7f3f-431b-b6fd-570251ba0d67.png?v=1787567159","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900cp1-0100-controledge-hc900-control-processor-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}