{"product_id":"honeywell-900g02-0102-16-channel-dc-digital-input-module-built","title":"Honeywell 900G02-0102 16-channel DC Digital Input Module Built","description":"\u003ch2\u003eHoneywell 900G02-0102 ControlEdge HC900 24VDC 16-Channel Extended Temperature Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900G02-0102\u003c\/strong\u003e is a \u003cstrong\u003e16-channel DC Digital Input Module\u003c\/strong\u003e built for the \u003cstrong\u003eControlEdge HC900\u003c\/strong\u003e platform, featuring an \u003cstrong\u003eextended operating temperature range\u003c\/strong\u003e of -40°C to +70°C. It accepts \u003cstrong\u003e24 VDC\u003c\/strong\u003e field signals and is organized into \u003cstrong\u003etwo groups of 8 channels\u003c\/strong\u003e. Each channel includes an individual \u003cstrong\u003egreen LED indicator\u003c\/strong\u003e for real-time status visibility, and controller logic supports input state inversion on a per-channel basis.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Honeywell ControlEdge HC900\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e DC Digital Input Module (Extended Temperature)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel Grouping:\u003c\/strong\u003e 2 groups of 8 channels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Green LED per channel (ON state); green blinking status LED (module scanning); red status LED (diagnostics)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eState Inversion:\u003c\/strong\u003e Supported via controller logic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Euro style (required, sold separately)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, cULus, ATEX (zone 2), IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePhysical \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Plugs into ControlEdge HC900 I\/O rack\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Compliant with IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e Compliant with IEC 60068-2-27\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Temp Design:\u003c\/strong\u003e Industrial-grade components rated for harsh ambient conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Racks:\u003c\/strong\u003e Honeywell ControlEdge HC900 I\/O racks (1-slot, 4-slot, 8-slot, 12-slot configurations)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Power Supplies:\u003c\/strong\u003e 900P01-0201 (120\/240VAC), 900P24-0501 (24VDC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e 900CP1-0100 \/ 900CP1-0200 \/ 900CP1-0300 Control Processor Modules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRequired Accessories:\u003c\/strong\u003e Euro style terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the HC900 rack before module insertion unless performing a controlled hot-swap operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the 900G02-0102 with the target I\/O slot and press firmly until the locking tab engages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Wiring:\u003c\/strong\u003e Install the Euro style terminal block. Connect 24 VDC field wiring to the input and common terminals per group. Ensure cable insulation is rated for the installation temperature range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower On \u0026amp; Verification:\u003c\/strong\u003e Apply rack power and confirm the green blinking status LED indicates normal scanning. Verify each input channel LED responds correctly to field signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Use ControlEdge Builder software to map channel addresses and configure state inversion if required.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Temperature:\u003c\/strong\u003e Select the 900G02-0102 when the installation environment exceeds 60°C or drops below 0°C. For standard indoor environments, the \u003cstrong\u003e900G02-0202\u003c\/strong\u003e (0°C to 60°C) offers equivalent functionality at standard specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Match:\u003c\/strong\u003e Verify all field devices operate at 24 VDC. This module does not support AC signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Order the compatible Euro style terminal block separately if not included in your system kit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e In sub-zero or high-heat environments, use industrial-grade cables with temperature ratings matching the -40°C to +70°C module specification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e For critical outdoor or unconditioned installations, pair with redundant power supplies and the 900PSM-0101 Power Status Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the difference between 900G02-0102 and 900G02-0202?\u003c\/h4\u003e\n\u003cp\u003eThe primary difference is the \u003cstrong\u003eoperating temperature range\u003c\/strong\u003e. The 900G02-0102 is rated for -40°C to +70°C (extended temperature), while the 900G02-0202 is rated for 0°C to 60°C (standard temperature). Both share identical channel count, voltage rating, and electrical architecture.\u003c\/p\u003e\n\n\u003ch4\u003eCan this module be used in outdoor installations?\u003c\/h4\u003e\n\u003cp\u003eYes, the extended temperature rating of \u003cstrong\u003e-40°C to +70°C\u003c\/strong\u003e makes the 900G02-0102 suitable for outdoor enclosures, remote pump stations, and unconditioned industrial environments. Ensure the enclosure provides appropriate IP protection for the specific location.\u003c\/p\u003e\n\n\u003ch4\u003eDoes this module support hot-swapping?\u003c\/h4\u003e\n\u003cp\u003eYes. The ControlEdge HC900 platform supports \u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e for I\/O modules. Follow proper ESD protocols and system documentation when performing hot-swaps.\u003c\/p\u003e\n\n\u003ch4\u003eWhat terminal block is required?\u003c\/h4\u003e\n\u003cp\u003eThe module requires a \u003cstrong\u003eEuro style terminal block\u003c\/strong\u003e. Confirm the exact part number with your Honeywell distributor.\u003c\/p\u003e\n\n\u003ch4\u003eIs this module compatible with third-party PLCs?\u003c\/h4\u003e\n\u003cp\u003eNo. The 900G02-0102 is designed exclusively for the \u003cstrong\u003eHoneywell ControlEdge HC900\u003c\/strong\u003e rack architecture.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOutdoor pump station and wellhead monitoring\u003c\/li\u003e\n  \u003cli\u003ePipeline flow and pressure switch interfacing\u003c\/li\u003e\n  \u003cli\u003eRemote terminal unit (RTU) digital input expansion\u003c\/li\u003e\n  \u003cli\u003eRefrigeration and cold storage facility control\u003c\/li\u003e\n  \u003cli\u003eDesert or arctic environment automation\u003c\/li\u003e\n  \u003cli\u003eOffshore platform and marine equipment status\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose the 900G02-0102?\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900G02-0102 delivers \u003cstrong\u003erugged 24 VDC digital input capability\u003c\/strong\u003e in an extended temperature package, ensuring reliable operation in the harshest industrial environments. Its -40°C to +70°C rating, per-channel LED diagnostics, and native HC900 integration make it the right choice for outdoor, remote, and extreme-condition automation projects.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53974751051960,"sku":"900G02-0102","price":138.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900G02-0102_2__.r180_d673ee7b-dde6-45aa-ad93-ba00aaed3117.png?v=1787567069","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900g02-0102-16-channel-dc-digital-input-module-built","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}