{"product_id":"honeywell-900h01-0102-relay-output-module-8-ch","title":"Honeywell 900H01-0102 Relay Output Module, 8 Ch","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900H01-0102\u003c\/strong\u003e is a \u003cstrong\u003eDigital Output Module\u003c\/strong\u003e providing \u003cstrong\u003e8 channels\u003c\/strong\u003e of \u003cstrong\u003e24 VDC transistor output\u003c\/strong\u003e for the Honeywell ControlEdge HC900 system. Featuring \u003cstrong\u003esourcing (PNP) outputs\u003c\/strong\u003e, this module drives 24 VDC loads such as solenoid valves, relay coils, and indicator lamps with fast switching response and electronic short-circuit protection. Transistor outputs offer longer life and faster switching than relay outputs for DC-only applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Transistor Output Channels:\u003c\/strong\u003e 24 VDC sourcing (PNP) outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Switching:\u003c\/strong\u003e Faster response than relay outputs for high-speed applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Protection:\u003c\/strong\u003e Short-circuit and overload protection per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LEDs:\u003c\/strong\u003e Per-channel output state indication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capable:\u003c\/strong\u003e Replace without system shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Standard HC900 module form factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 900H01-0102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Digital Output Module (Transistor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlEdge HC900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Sourcing (PNP) transistor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e Per-channel rated (refer to system documentation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Electronic short-circuit, overload\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5V: 300 mA max; 24V: per load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e ~1.5W (base) + load dissipation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 137 mm H × 35.6 mm W (5.4\" H × 1.4\" W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~210 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Chassis slot mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion:\u003c\/strong\u003e Install in HC900 I\/O rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Use 900TEK\/900TBK terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Wiring:\u003c\/strong\u003e Connect 24 VDC loads between output and common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Ensure 24 VDC supply adequate for total load current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Loads:\u003c\/strong\u003e Install flyback diodes for solenoids and relay coils\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Set output logic in ControlEdge Builder\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 900H01-0102 and 900H01-0202?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; 900H01-0202 is a later revision. Both are 8-channel 24 VDC transistor output modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can transistor outputs switch AC loads?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; No. Transistor outputs are DC-only. For AC loads, use \u003cstrong\u003e900H02\u003c\/strong\u003e relay output modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens during a short circuit?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The affected channel enters current-limiting mode. The fault is reported to the controller, and the channel automatically resets when the short is removed.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse 900H01-0102 for DC-only applications requiring fast switching\u003c\/li\u003e\n\u003cli\u003eCalculate total load current to ensure 24 VDC supply capacity\u003c\/li\u003e\n\u003cli\u003eFor AC loads or galvanic isolation, use \u003cstrong\u003e900H02\u003c\/strong\u003e relay outputs instead\u003c\/li\u003e\n\u003cli\u003eInstall external flyback diodes for all inductive DC loads\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53827416883384,"sku":"900H01-0102","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900H01-0102_3r180.png?v=1785223055","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900h01-0102-relay-output-module-8-ch","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}