{"product_id":"honeywell-900h02-0202-controledge-hc900-24vdc-16-channel-sinking-digital-output-module","title":"Honeywell 900H02-0202 ControlEdge HC900 24VDC 16-Channel Sinking Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900H02-0202\u003c\/strong\u003e is a \u003cstrong\u003e16-channel 24VDC sinking digital output module\u003c\/strong\u003e for the Honeywell ControlEdge HC900 PLC system. This module provides high-side switching (current sinking) outputs for controlling DC-powered field devices, with overcurrent protection organized in groups for reliable industrial operation.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 digital outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 6.5–32 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Sinking (high-side switching)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Channel:\u003c\/strong\u003e 1 A continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Module Current:\u003c\/strong\u003e 8 A total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 340 mA @ 5VDC (from rack backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 6 ms ON \/ 6 ms OFF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Grouping:\u003c\/strong\u003e 2 groups of 8 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Per group (8 channels per group)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e Green LED per channel, scan\/fault LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe 900H02-0202 is compatible with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRacks:\u003c\/strong\u003e All HC900 4-slot, 8-slot, and 12-slot racks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Modules:\u003c\/strong\u003e All 900CP1 series CPMs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks:\u003c\/strong\u003e Compatible with barrier and Euro-style terminal blocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower down:\u003c\/strong\u003e De-energize the HC900 rack before module installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert module:\u003c\/strong\u003e Install the \u003cstrong\u003e900H02-0202\u003c\/strong\u003e into any available I\/O slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure module:\u003c\/strong\u003e Lock the retention lever to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire outputs:\u003c\/strong\u003e Connect field device positive (+) to the output terminal and negative (-) to the COM terminal for each group.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply power:\u003c\/strong\u003e Energize the rack and verify green LEDs illuminate when outputs are commanded ON.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest overcurrent:\u003c\/strong\u003e Verify that a short circuit on any channel disables only its group of 8 channels.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens during an overcurrent event?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If any channel in a group of 8 experiences a short circuit, the \u003cstrong\u003eentire group is switched off\u003c\/strong\u003e. Power cycling is \u003cstrong\u003enot required\u003c\/strong\u003e to reset the module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix sourcing and sinking outputs in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The HC900 rack supports both \u003cstrong\u003e900H02-0202 (sinking)\u003c\/strong\u003e and \u003cstrong\u003e900H32-0302 (sourcing)\u003c\/strong\u003e modules simultaneously.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum inrush current?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports \u003cstrong\u003e2A inrush current\u003c\/strong\u003e for 100 ms per channel.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse the \u003cstrong\u003e900H02-0202\u003c\/strong\u003e for \u003cstrong\u003eDC sinking applications\u003c\/strong\u003e where field devices share a common positive supply.\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003esourcing applications\u003c\/strong\u003e (current sourcing to loads), select the \u003cstrong\u003e900H32-0302\u003c\/strong\u003e 32-channel module.\u003c\/li\u003e\n\u003cli\u003eEnsure total module current does not exceed \u003cstrong\u003e8A\u003c\/strong\u003e. Distribute high-current loads across multiple modules if necessary.\u003c\/li\u003e\n\u003cli\u003eWire each group of 8 channels to a separate COM terminal for optimal fault isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eStandards \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Marked\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eCSA Certified\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53974720053432,"sku":"900H02-0202","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900H02-0202_._52a12b64-115e-46dc-9cb9-c654db9e484d.png?v=1787565707","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900h02-0202-controledge-hc900-24vdc-16-channel-sinking-digital-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}