{"product_id":"honeywell-900h03-0001-8-channel-ac-digital-output-module","title":"Honeywell 900H03-0001 8-Channel AC Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n    \u003cp\u003eThe \u003cstrong\u003eHoneywell 900H03-0001\u003c\/strong\u003e is an \u003cstrong\u003e8-channel AC digital output module\u003c\/strong\u003e designed for the \u003cstrong\u003eControlEdge HC900\u003c\/strong\u003e controller family. Featuring \u003cstrong\u003eTriac outputs\u003c\/strong\u003e rated for \u003cstrong\u003e85–240 VAC\u003c\/strong\u003e, this module provides isolated, high-voltage switching for AC loads such as solenoid valves, contactor coils, indicator lamps, and motor starters. With individual channel isolation, built-in surge protection, and compact design, the 900H03-0001 is ideal for industrial automation applications requiring reliable AC load control.\u003c\/p\u003e\n\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003e8 isolated Triac output channels\u003c\/strong\u003e for AC load switching\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eWide voltage range:\u003c\/strong\u003e 85–240 VAC per channel\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHigh current capacity:\u003c\/strong\u003e up to \u003cstrong\u003e2 A per channel\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndividual channel isolation\u003c\/strong\u003e for noise immunity and safety\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eBuilt-in surge protection\u003c\/strong\u003e for inductive load switching\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndividual LED status indicators\u003c\/strong\u003e for each output channel\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompact modular design\u003c\/strong\u003e for HC900 rack mounting\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 900H03-0001\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 8-Channel AC Digital Output Module\u003c\/li\u003e        \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlEdge HC900\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e \u003cstrong\u003eTriac (isolated)\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e \u003cstrong\u003e85–240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 120–240 VAC (line voltage following)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLoad Current per Channel:\u003c\/strong\u003e \u003cstrong\u003e0–2 A\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e \u003cstrong\u003e5 VDC @ 218 mA\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel and channel-to-system isolation\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e Built-in snubber circuit for inductive loads\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e Individual LED per channel\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDimensions (L × W × H):\u003c\/strong\u003e \u003cstrong\u003e100 × 70 × 25 mm\u003c\/strong\u003e (3.9\" × 2.8\" × 1.0\")\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. \u003cstrong\u003e0.3 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong\u003e0°C to +60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e −40°C to +85°C\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e HC900 rack slot\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eTypical Applications\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003eAC solenoid valve control\u003c\/li\u003e\n        \u003cli\u003eContactor and relay coil driving\u003c\/li\u003e        \u003cli\u003eAC indicator lamp and alarm horn control\u003c\/li\u003e\n        \u003cli\u003eMotor starter control circuits\u003c\/li\u003e\n        \u003cli\u003eHeater and fan AC load switching\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eFAQ\u003c\/h3\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: What type of outputs does the 900H03-0001 provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides \u003cstrong\u003e8 Triac outputs\u003c\/strong\u003e for switching AC loads in the \u003cstrong\u003e85–240 VAC\u003c\/strong\u003e range.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: What is the maximum current per channel?\u003c\/strong\u003e\u003cbr\u003eA: Each channel supports up to \u003cstrong\u003e2 A\u003c\/strong\u003e of AC load current.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: Are the outputs isolated?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eYes.\u003c\/strong\u003e Each channel features \u003cstrong\u003eindividual isolation\u003c\/strong\u003e from the system and from other channels, providing excellent noise immunity and safety.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: Can this module drive inductive loads?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eYes.\u003c\/strong\u003e The built-in \u003cstrong\u003esnubber circuit\u003c\/strong\u003e protects the Triac outputs when switching inductive loads such as contactor coils and solenoids.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e        \u003cp\u003e\u003cstrong\u003eQ: What is the difference between 900H03-0001 and 900H03-0202?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e900H03-0001\u003c\/strong\u003e is a legacy revision. The \u003cstrong\u003e900H03-0202\u003c\/strong\u003e is a current-generation equivalent. Both provide 8-channel 120\/240 VAC Triac outputs. Verify controller firmware compatibility.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n    \u003col\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePower Off:\u003c\/strong\u003e De-energize the HC900 rack before installing the 900H03-0001.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSlot Insertion:\u003c\/strong\u003e Insert the module into an available I\/O slot and press firmly until the retention clips engage.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect AC loads to the module terminals using appropriate high-voltage wiring (typically 14–18 AWG). Ensure proper torque on terminal screws.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLoad Verification:\u003c\/strong\u003e Verify each load does not exceed 2 A continuous. For inductive loads, ensure the snubber circuit is adequate or add external protection if necessary.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFusing:\u003c\/strong\u003e Install external fuses or circuit breakers for each channel to protect against overload conditions.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eStatus Check:\u003c\/strong\u003e Power on the rack and activate each output via the PLC program. Confirm the corresponding LED illuminates and the load operates correctly.\u003c\/li\u003e\n    \u003c\/ol\u003e\n\n    \u003ch3\u003eSelection Tips\u003c\/h3\u003e\n    \u003cul\u003e        \u003cli\u003eChoose the \u003cstrong\u003e900H03-0001\u003c\/strong\u003e for \u003cstrong\u003e8-channel AC load switching\u003c\/strong\u003e with individual channel isolation.\u003c\/li\u003e\n        \u003cli\u003eIf you need \u003cstrong\u003emore AC output channels\u003c\/strong\u003e, consider the \u003cstrong\u003e900H03-0202\u003c\/strong\u003e (current revision) or add additional 900H03 modules.\u003c\/li\u003e\n        \u003cli\u003eFor \u003cstrong\u003eDC output switching\u003c\/strong\u003e, use the \u003cstrong\u003e900H32-0302\u003c\/strong\u003e (24 VDC, 32-channel) or \u003cstrong\u003e900H02-0102\u003c\/strong\u003e (24 VDC, 16-channel).\u003c\/li\u003e\n        \u003cli\u003eFor \u003cstrong\u003erelay outputs\u003c\/strong\u003e (isolated dry contacts), use the \u003cstrong\u003e900H01-0202\u003c\/strong\u003e relay output module.\u003c\/li\u003e\n        \u003cli\u003eAlways install \u003cstrong\u003eexternal fusing\u003c\/strong\u003e per channel to protect the Triac outputs from overload.\u003c\/li\u003e\n        \u003cli\u003eEnsure \u003cstrong\u003etotal rack power budget\u003c\/strong\u003e accounts for the 218 mA @ 5 VDC module draw.\u003c\/li\u003e\n    \u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53960112668856,"sku":"900H03-0001","price":111.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900H03-0001_2.png?v=1787196894","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900h03-0001-8-channel-ac-digital-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}