{"product_id":"honeywell-900sp1-0300-expansion-processor-module","title":"Honeywell 900SP1-0300 Expansion Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n    \u003cp\u003eThe \u003cstrong\u003eHoneywell 900SP1-0300\u003c\/strong\u003e is an \u003cstrong\u003eExpansion Processor Module (EPM)\u003c\/strong\u003e for the \u003cstrong\u003eControlEdge 900\u003c\/strong\u003e series. Acting as the communication bridge between expansion I\/O racks and the Control Processor Module (CPM), the 900SP1-0300 enables scalable, distributed control architectures. With a \u003cstrong\u003edual-core ARM® Cortex™-A9 processor\u003c\/strong\u003e, dual Ethernet ports, and robust isolation, this module is engineered for high-availability process automation in extreme industrial environments.\u003c\/p\u003e\n\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDual-Core ARM® Cortex™-A9 processor\u003c\/strong\u003e at 667 MHz for high-speed data handling\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2 × RJ45 Ethernet ports\u003c\/strong\u003e with auto-crossover and 10\/100BaseTx auto-detection\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e1500 V RMS isolation\u003c\/strong\u003e for 1 minute — protects against electrical noise and ground loops\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e600 W peak pulse power\u003c\/strong\u003e transient protection (10×1000 μs waveform)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExtended temperature range:\u003c\/strong\u003e −40°C to +70°C\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eRotary switch addressing\u003c\/strong\u003e (1–99) for simple rack identification\u003c\/li\u003e\n        \u003cli\u003eDual three-color \u003cstrong\u003eLED diagnostics\u003c\/strong\u003e per port for instant status visibility\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cul\u003e        \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 900SP1-0300\u003c\/li\u003e        \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Expansion Processor Module (EPM)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlEdge 900 \/ HC900\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Dual-Core ARM® Cortex™-A9 (32-bit) at \u003cstrong\u003e667 MHz\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e 2 × RJ45, shielded, auto-crossover\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNetwork Speed:\u003c\/strong\u003e 10\/100BaseTx, auto-detecting\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cstrong\u003e1500 V RMS\u003c\/strong\u003e for 1 minute (60 Hz)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eVoltage Suppression:\u003c\/strong\u003e \u003cstrong\u003e600 W peak pulse power\u003c\/strong\u003e at 10×1000 μs waveform\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 520 mA operating, 0 mA idle, \u003cstrong\u003e2.6 W max\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAddress Configuration:\u003c\/strong\u003e Rotary switch (1–99)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e 2 three-color LEDs + per-port LEDs\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong\u003e−40°C to +70°C\u003c\/strong\u003e\n\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 137 mm H × 38.1 mm W (5.4\" H × 1.5\" W)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong\u003e320 g\u003c\/strong\u003e (0.7 lbs)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA, TÜV\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eTypical Applications\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003eDistributed I\/O rack expansion in process plants\u003c\/li\u003e\n        \u003cli\u003eRemote rack communication in large-scale DCS architectures\u003c\/li\u003e        \u003cli\u003eSafety instrumented system (SIS) I\/O extension\u003c\/li\u003e        \u003cli\u003eOil \u0026amp; gas pipeline and terminal automation\u003c\/li\u003e\n        \u003cli\u003eChemical and pharmaceutical batch control\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eFAQ\u003c\/h3\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: What is the function of the 900SP1-0300?\u003c\/strong\u003e\u003cbr\u003eA: It acts as the \u003cstrong\u003einterface between expansion I\/O racks and the Control Processor Module (CPM)\u003c\/strong\u003e, enabling distributed control architectures.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: How many Ethernet ports does it have?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eTwo RJ45 Ethernet ports\u003c\/strong\u003e with auto-crossover, supporting 10\/100BaseTx speeds.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003e−40°C to +70°C\u003c\/strong\u003e, making it suitable for extreme industrial environments.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: How is the rack address configured?\u003c\/strong\u003e\u003cbr\u003eA: Via a \u003cstrong\u003erotary switch\u003c\/strong\u003e on the module front panel, supporting addresses \u003cstrong\u003e1 through 99\u003c\/strong\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n        \u003cp\u003e\u003cstrong\u003eQ: Is the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e Rack power must be removed before inserting or removing the expansion processor module.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n    \u003col\u003e        \u003cli\u003e\n\u003cstrong\u003ePower Off:\u003c\/strong\u003e Ensure the HC900 rack is completely de-energized before installing the 900SP1-0300.\u003c\/li\u003e        \u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Insert the module into the designated expansion processor slot in the I\/O rack. Press firmly until fully seated.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAddress Setting:\u003c\/strong\u003e Use the rotary switch to set the unique rack address (1–99) before powering on.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect shielded CAT5e\/CAT6 cables to the RJ45 ports. Use auto-crossover capability to simplify switch connections.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNetwork Verification:\u003c\/strong\u003e Power on and verify link LEDs illuminate. Check communication status in the Hybrid Control Designer software.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExpansion Rack Daisy-Chain:\u003c\/strong\u003e If connecting multiple expansion racks, plan network topology to ensure adequate bandwidth and switch port capacity.\u003c\/li\u003e\n    \u003c\/ol\u003e\n\n    \u003ch3\u003eSelection Tips\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003eSelect the \u003cstrong\u003e900SP1-0300\u003c\/strong\u003e for \u003cstrong\u003eControlEdge 900 \/ HC900 systems\u003c\/strong\u003e requiring remote I\/O rack expansion.\u003c\/li\u003e\n        \u003cli\u003eFor \u003cstrong\u003elegacy HC900 systems\u003c\/strong\u003e, verify compatibility with your controller firmware revision.\u003c\/li\u003e\n        \u003cli\u003eEnsure \u003cstrong\u003eEthernet switch ports\u003c\/strong\u003e support the required 10\/100BaseTx speed and have sufficient capacity for all expansion racks.\u003c\/li\u003e        \u003cli\u003eUse \u003cstrong\u003eshielded industrial Ethernet cables\u003c\/strong\u003e to maintain signal integrity in electrically noisy environments.\u003c\/li\u003e        \u003cli\u003ePlan \u003cstrong\u003erack addressing\u003c\/strong\u003e in advance to avoid conflicts in multi-rack configurations.\u003c\/li\u003e\n    \u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53959834501304,"sku":"900SP1-0300","price":162.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900SP1-0300_1.png?v=1787197556","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900sp1-0300-expansion-processor-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}