{"product_id":"honeywell-cc-pdob01-51405043-175-digital-output-24v-module","title":"Honeywell CC-PDOB01 51405043-175 Digital Output 24V Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PDOB01 51405043-175 is a 32-channel Bussed Digital Output (DO) module designed for the Experion Series C I\/O platform. It provides 24 V DC sourcing outputs to drive field loads such as solenoids, relays, and indicator lights, utilizing a high-density bussed power distribution architecture via the IOTA.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInput \/ Output Model: CC-PDOB01 - Digital Output 24 VDC (Bussed)\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51405043-175\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520_V10_SCIO_1_5)\u003c\/li\u003e\n  \u003cli\u003eOutput Channels: 32 Channels\u003c\/li\u003e\n  \u003cli\u003eOutput Type: Sourcing (Provides 24 V DC to the field load from a common bus)\u003c\/li\u003e\n  \u003cli\u003eNominal Supply Voltage: 24 V DC\u003c\/li\u003e\n  \u003cli\u003eGalvanic Isolation: 1500 VDC (Channel-to-system and channel-to-frame isolation)\u003c\/li\u003e\n  \u003cli\u003eSafe-State Behaviors (FAILOPT): Configurable on a per-channel basis (Hold Last Value or Off\/Safe Value)\u003c\/li\u003e\n  \u003cli\u003eShort-Circuit Protection: Electronic current-limiting circuitry per channel\u003c\/li\u003e\n  \u003cli\u003eOn-board Diagnostics: Extensive module self-diagnostics with fault discrepancy reporting\u003c\/li\u003e\n  \u003cli\u003eConformal Coating: Yes (Standard ISA-S71.04 Class G3 environmental coating protection)\u003c\/li\u003e\n  \u003cli\u003eRedundancy Support: Optional (via specific Redundant Bussed DO IOTA blocks)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TDOB01:\u003c\/strong\u003e Series C Digital Output Bussed Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TDOB11:\u003c\/strong\u003e Series C Digital Output Bussed Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GDOB11:\u003c\/strong\u003e Series C Digital Output Bussed Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GDOB21:\u003c\/strong\u003e Series C Digital Output Bussed Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBussed Power Distribution:\u003c\/strong\u003e Features a group-bussed power design through the IOTA backplane, simplifying field wiring by routing a common 24 V DC supply across channel clusters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFAILOPT Configuration:\u003c\/strong\u003e Supports configurable fail-option parameters defined per channel. If the controller communication drops, channels can be independent set to \u003cem\u003eHOLD LAST VALUE\u003c\/em\u003e or \u003cem\u003eSHED TO SAFE VALUE (OFF)\u003c\/em\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Read-back Verification:\u003c\/strong\u003e Onboard logic continuously reads back the actual electrical state of the output switches and triggers a system alarm if a discrepancy with the commanded logic state is detected.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectronic Short-Circuit Safeguards:\u003c\/strong\u003e Protects internal card components against field wiring faults and shorted solenoids without requiring external inline glass fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSeat the CC-PDOB01 module onto its designated 6-inch non-redundant (CC-TDOB01\/GDOB21) or 12-inch redundant (CC-TDOB11\/GDOB11) IOTA terminal block.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the aggregate current draw of all active field devices connected to the common bus does not exceed the maximum thermal and current load capacity specified for the IOTA board.\u003c\/li\u003e\n  \u003cli\u003eTighten the integrated module mounting fasteners to ensure robust mechanical grounding and electrical backplane continuity.\u003c\/li\u003e\n  \u003cli\u003eDefine specific channel-level FAILOPT parameters and initial state variables in the Experion Control Builder utility prior to downloading the active control strategies to the C300 controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617877942456,"sku":"51405043-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PDOB01r270.png?v=1782201390","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-cc-pdob01-51405043-175-digital-output-24v-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}