{"product_id":"honeywell-fc-fanwr-24r-fan-assembly-kit-24-vdc-redundant","title":"Honeywell FC-FANWR-24R Fan Assembly Kit (24 VDC, Redundant)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-FANWR-24R\u003c\/strong\u003e is a \u003cstrong\u003eRedundant Fan Module\u003c\/strong\u003e providing \u003cstrong\u003eforced air cooling\u003c\/strong\u003e for Honeywell Safety Manager chassis and cabinets. Operating on \u003cstrong\u003e24 VDC\u003c\/strong\u003e, this module ensures adequate airflow to maintain safe operating temperatures for I\/O modules, power supplies, and controllers. The redundant design provides continued cooling even if one fan fails, enhancing system reliability in high-temperature or high-density installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Redundant Fans:\u003c\/strong\u003e Two independent fans for fault-tolerant cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Operation:\u003c\/strong\u003e Standard industrial voltage compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Control:\u003c\/strong\u003e Thermostatic or continuous operation (verify variant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e Fan speed and fault detection with alarm output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capable:\u003c\/strong\u003e Replaceable without system shutdown (verify process impact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Compatible:\u003c\/strong\u003e Accepts standard air filters for dusty environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FC-FANWR-24R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Redundant Fan Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan Count:\u003c\/strong\u003e 2 (redundant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow:\u003c\/strong\u003e Refer to system documentation (typically 50-100 CFM per fan)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Level:\u003c\/strong\u003e Low-noise design for control room environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter:\u003c\/strong\u003e Standard filter slot (filter ordered separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Chassis or cabinet mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C (fan operation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in designated fan slot or cabinet ventilation opening\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect 24 VDC supply with proper polarity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Direction:\u003c\/strong\u003e Verify airflow direction matches system cooling design (intake vs. exhaust)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Installation:\u003c\/strong\u003e Install air filter if operating in dusty environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Connect fault alarm output to system monitoring\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if one fan fails?\u003c\/strong\u003e\u003cbr\u003eA: The redundant fan continues operation. A fault alarm is generated to alert maintenance personnel. Replace the failed fan at the earliest opportunity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How often should filters be replaced?\u003c\/strong\u003e\u003cbr\u003eA: Filter replacement frequency depends on environmental conditions. Inspect monthly in dusty environments; replace when visibly dirty or when airflow is restricted.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this required for all Safety Manager installations?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Fan modules are recommended for high-density installations, high-temperature environments, or when chassis power dissipation exceeds passive cooling capacity. Calculate thermal requirements for your specific application.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse for installations where passive cooling is insufficient\u003c\/li\u003e\n\u003cli\u003eVerify cabinet airflow design (intake at bottom, exhaust at top)\u003c\/li\u003e\n\u003cli\u003eConsider environmental dust levels when specifying filters\u003c\/li\u003e\n\u003cli\u003eFor non-redundant applications, verify if single-fan variant is available\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53811812073656,"sku":"FC-FANWR-24R","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-FANWR-24R_2__.r180.png?v=1785134502","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-fc-fanwr-24r-fan-assembly-kit-24-vdc-redundant","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}