{"product_id":"honeywell-fc-tsai-1620m-analog-input-module","title":"Honeywell FC-TSAI-1620m Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-TSAI-1620m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog input module designed for integration with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. It provides a critical interface for acquiring safety-related analog field signals with the diagnostic coverage and fault tolerance required for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL-rated Safety Instrumented Functions (SIF)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for precision and reliability, the module supports 16 analog input channels commonly used for pressure, temperature, and flow transmitters in safety-critical loops. Its compact form factor, low signal drift, and strong immunity to electromagnetic interference make it well suited for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFire \u0026amp; Gas (F\u0026amp;G)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-TSAI-1620m (TSAI-1620m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA or 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit to 16-bit (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 2 \/ SIL 3 (with redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow, optimized for reduced heat dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e21.0 × 7.0 × 5.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication \u0026amp; Integration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-TSAI-1620m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis installed in the Safety Manager I\/O chassis and optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“m” series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehigh-availability configurations. It converts analog field signals into digital values evaluated by the safety processor against configured trip limits and safety logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRefinery Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVessel pressure and combustible gas monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-integrity steam temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOffshore Platforms:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESD signal acquisition in space-constrained areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “m” suffix indicate?\u003c\/strong\u003e\u003cbr\u003eIt denotes compatibility with specific Safety Manager backplanes or a modernized hardware revision offering improved diagnostics and higher channel density.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. When used within the Safety Manager system and following approved safety procedures, the module supports online replacement without a system shutdown.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52495016919224,"sku":"FC-TSAI-1620M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-TSAI-1620M.jpg?v=1769153720","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-fc-tsai-1620m-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}