{"product_id":"honeywell-fc-tsdo-0824-safe-digital-output-field-termination-assembly","title":"Honeywell FC-TSDO-0824 Safe Digital Output Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSDO-0824\u003c\/strong\u003e is a \u003cstrong\u003eSafe Digital Output Field Termination Assembly (FTA)\u003c\/strong\u003e providing \u003cstrong\u003e8 channels\u003c\/strong\u003e of \u003cstrong\u003e24 VDC digital output\u003c\/strong\u003e for Honeywell Safety Manager systems. It interfaces the safety controller with field actuators such as solenoid valves, motor starters, and alarm horns, delivering reliable switching with integrated diagnostics and short-circuit protection for safety-critical applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Safe Digital Outputs:\u003c\/strong\u003e 24 VDC sourcing outputs for actuator control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Per-channel protection with automatic reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interconnection:\u003c\/strong\u003e SIC cable interface to redundant SDO-0824 I\/O modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LEDs:\u003c\/strong\u003e Per-channel indication for output state and fault diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Universal snap-in for TS32\/TS35 rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Space-efficient for dense control panel layouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FS-TSDO-0824 (also FC-TSDO-0824)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Safe Digital Output FTA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 digital outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.5 A per channel (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Current:\u003c\/strong\u003e 4 A maximum (all channels combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Electronic, automatic reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 60 × 70 × 58 mm (L × W × H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e Max 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip Length:\u003c\/strong\u003e 7 mm (0.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.5 Nm (0.37 ft-lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TÜV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Snap FTA onto TS32\/TS35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator Wiring:\u003c\/strong\u003e Connect solenoid valves, motor starters, or other 24 VDC actuators to screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Ensure 24 VDC supply can support total load current (max 4 A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIC Cable:\u003c\/strong\u003e Plug SIC-C-12 system interconnection cable into SIC connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e For redundant SDO-0824 modules, connect both FTAs to paired I\/O modules\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum load per channel?\u003c\/strong\u003e\u003cbr\u003eA: Each channel can source up to 0.5 A. The total combined load across all 8 channels must not exceed 4 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this drive inductive loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but external flyback diodes are recommended for inductive loads (solenoids, relays) to protect output transistors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens during a short circuit?\u003c\/strong\u003e\u003cbr\u003eA: The affected channel enters current-limiting mode. The fault is reported to the safety controller, and the channel automatically resets when the short is removed.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCalculate total load current to ensure power supply adequacy (max 4 A combined)\u003c\/li\u003e\n\u003cli\u003eFor higher current requirements, use relay output modules or external relays\u003c\/li\u003e\n\u003cli\u003eEnsure paired I\/O module is SDO-0824 installed in the chassis\u003c\/li\u003e\n\u003cli\u003eFor SIL 3 applications, use redundant SDO-0824 module pairs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53811831013560,"sku":"FC-TSDO-0824","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-TSDO-0824_1__.r180.png?v=1785134504","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-fc-tsdo-0824-safe-digital-output-field-termination-assembly","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}