{"product_id":"honeywell-fs-16di-rl-relay-input-terminal-board","title":"Honeywell FS-16DI-RL Relay Input Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-16DI-RL\u003c\/strong\u003e is a \u003cstrong\u003e16-channel digital input module\u003c\/strong\u003e designed for Honeywell Safety Manager systems. It provides reliable acquisition of discrete signals from field devices in safety-critical industrial applications. With low-power consumption design and wide voltage tolerance, this module ensures accurate status monitoring for emergency shutdown systems, process interlocks, and safety instrumented systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Input Channels:\u003c\/strong\u003e High-density discrete signal acquisition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage Range:\u003c\/strong\u003e 10–30 VDC input tolerance for flexible field device compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Energy-efficient design reduces system power requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpto-Isolated Inputs:\u003c\/strong\u003e Electrical isolation protects internal circuitry from field transients\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LEDs:\u003c\/strong\u003e Per-channel indication for quick diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Standard 4TE module width for efficient chassis utilization\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FS-16DI-RL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 16-Channel Digital Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Digital, discrete signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 10–30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e Low-power consumption design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Opto-isolated per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Width:\u003c\/strong\u003e 4 TE (20.32 mm \/ 0.8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion:\u003c\/strong\u003e Slide module into designated slot until flush with chassis front\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat Cable Connection:\u003c\/strong\u003e Connect horizontal IO bus flat cable to module front connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Termination:\u003c\/strong\u003e Use compatible FTA (e.g., FC-TSDI-1624) for field wiring interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Assignment:\u003c\/strong\u003e Module address determined by slot position—no jumpers or switches needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap:\u003c\/strong\u003e Module can be replaced with power on; verify process impact before removal\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require an FTA?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The FS-16DI-RL is the I\/O module installed in the chassis. Field wiring connects via a compatible Field Termination Assembly (FTA) such as FC-TSDI-1624.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can inputs from different voltage sources be mixed?\u003c\/strong\u003e\u003cbr\u003eA: All 16 channels share common configuration. Verify field device voltage compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the replacement procedure?\u003c\/strong\u003e\u003cbr\u003eA: Disconnect flat cable, loosen screws, slide out old module, insert new module, reconnect flat cable. Address is automatic based on slot position.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify voltage compatibility with field devices (10–30 VDC range)\u003c\/li\u003e\n\u003cli\u003ePair with appropriate FTA based on wiring requirements (screw terminals, wire gauge)\u003c\/li\u003e\n\u003cli\u003eFor SIL-rated applications, ensure complete safety loop calculation includes this module\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53811767705784,"sku":"FS-16DI-RL","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FS-16DI-RLr180.png?v=1785134550","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-fs-16di-rl-relay-input-terminal-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}