{"product_id":"honeywell-fs-tsfire-1624-safe-fire-detector-input-field-termination-assembly","title":"Honeywell FS-TSFIRE-1624 Safe Fire Detector Input Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSFIRE-1624\u003c\/strong\u003e is a specialized \u003cstrong\u003eSafe Fire Detector Input Field Termination Assembly (FTA)\u003c\/strong\u003e providing \u003cstrong\u003e16 channels\u003c\/strong\u003e for fire and gas detection devices in Honeywell Safety Manager systems. Designed specifically for fire alarm loops and gas detector inputs, this FTA includes enhanced line monitoring and fault detection capabilities required for life safety and fire protection applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Fire Detector Inputs:\u003c\/strong\u003e Dedicated channels for fire and gas detection devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Line Monitoring:\u003c\/strong\u003e Detects open circuits, short circuits, and ground faults in detector loops\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd-of-Line Resistor Support:\u003c\/strong\u003e Compatible with standard fire alarm EOL resistor configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interconnection:\u003c\/strong\u003e SIC cable interface to SFIRE-1624 I\/O modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire \u0026amp; Gas Certified:\u003c\/strong\u003e Suitable for NFPA and EN 54 fire detection applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Universal snap-in for TS32\/TS35 rails\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FS-TSFIRE-1624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Safe Fire Detector Input FTA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 fire\/gas detector inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Compatible with conventional fire detectors, gas detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Monitoring:\u003c\/strong\u003e Open circuit, short circuit, ground fault detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEOL Resistor:\u003c\/strong\u003e Supports standard end-of-line resistor configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e Max 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TÜV, UL, CSA, FM, Fire \u0026amp; Gas certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Snap FTA onto TS32\/TS35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector Wiring:\u003c\/strong\u003e Connect fire detectors or gas detectors to screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEOL Resistor:\u003c\/strong\u003e Install end-of-line resistors per detector manufacturer specification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Verification:\u003c\/strong\u003e Use Safety Manager diagnostics to verify loop integrity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIC Cable:\u003c\/strong\u003e Connect to SFIRE-1624 I\/O module in chassis\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this be used with addressable fire detectors?\u003c\/strong\u003e\u003cbr\u003eA: The FS-TSFIRE-1624 is designed for conventional (non-addressable) fire detectors. For addressable loops, use dedicated addressable fire alarm interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of fire detectors are compatible?\u003c\/strong\u003e\u003cbr\u003eA: Compatible with smoke detectors, heat detectors, flame detectors, and manual call points that provide dry contact or current-limited outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this certified for fire alarm systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this FTA is suitable for fire and gas detection applications when used with certified Safety Manager configurations.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse specifically for fire and gas detection input applications\u003c\/li\u003e\n\u003cli\u003eVerify detector compatibility and EOL resistor requirements\u003c\/li\u003e\n\u003cli\u003eEnsure fire alarm system design complies with local codes (NFPA, EN 54)\u003c\/li\u003e\n\u003cli\u003eConsider separate FTAs for fire vs. gas detection to simplify maintenance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53811800277176,"sku":"FS-TSFIRE-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FS-TSFIRE-1624r180.png?v=1785134550","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-fs-tsfire-1624-safe-fire-detector-input-field-termination-assembly","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}