{"product_id":"honeywell-series-c-cc-paon01-51410070-175-analog-output-ao-module","title":"Honeywell Series C CC-PAON01 51410070-175 Analog Output (AO) Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAON01 51410070-175 is a 16-channel Non-HART High-Level Analog Output (AO) module designed for the Experion Series C I\/O platform. It delivers high-level constant current to actuators and recording\/indicating devices directly from the C300 controller, configured without HART pass-through requirements.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInput \/ Output Model: CC-PAON01 - High-Level Analog Output Non-HART\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51410070-175\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520_V10_SCIO_1_5)\u003c\/li\u003e\n  \u003cli\u003eOutput Type: 4-20 mA\u003c\/li\u003e\n  \u003cli\u003eOutput Channels: 16\u003c\/li\u003e\n  \u003cli\u003eOutput Ripple: \u0026lt; 100 mV peak-to-peak at power line frequency, across 250 Ω load\u003c\/li\u003e\n  \u003cli\u003eOutput Temperature Drift: 0.005% of Full Scale\/°C\u003c\/li\u003e\n  \u003cli\u003eOutput Readback Accuracy: ±4% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eOutput Current Linearity: ± 0.05% of Full Scale nominal\u003c\/li\u003e\n  \u003cli\u003eResolution: ± 0.05% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eCalibrated Accuracy: ± 0.35% of Full Scale (25°C) including linearity\u003c\/li\u003e\n  \u003cli\u003eDirectly Settable Output Current Range: 0 mA, 2.9 mA to 21.1 mA\u003c\/li\u003e\n  \u003cli\u003eMaximum Resistive Load (24 V supply = 22 VDC through 28 VDC): 800 ohms\u003c\/li\u003e\n  \u003cli\u003eMaximum Output Compliant Voltage (24 V supply = 22 VDC through 28 VDC): 16 V\u003c\/li\u003e\n  \u003cli\u003eMaximum Open Circuit Voltage: 22 V\u003c\/li\u003e\n  \u003cli\u003eResponse Time (DAC input code to output): Settles to within 1% of final value within 80 ms\u003c\/li\u003e\n  \u003cli\u003eGap (0 mA) of Output to Field on Switchover: 10 ms maximum (applies to Redundancy only)\u003c\/li\u003e\n  \u003cli\u003eOptional Redundancy: Supported\u003c\/li\u003e\n  \u003cli\u003eNon-incendive Output: Supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX01:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX21:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFAILOPT Behavior:\u003c\/strong\u003e Supports the FAILOPT parameter on a per-channel basis. The user can configure each channel to either \u003cem\u003eHOLD LAST VALUE\u003c\/em\u003e or \u003cem\u003eSHED to a SAFE VALUE\u003c\/em\u003e. The Output will always go to zero, the safe state, if the IOM device electronics fails.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen-wire Detection:\u003c\/strong\u003e Able to detect and annunciate open field wire with a Channel Soft Failure indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Read-back:\u003c\/strong\u003e Features output read-back and alarm on tracking discrepancy detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInsert the CC-PAON01 module onto its matched IOTA slot allocation (CC-TAOX01, CC-TAOX11, CC-GAOX11, or CC-GAOX21) inside the control cabinet enclosure.\u003c\/li\u003e\n  \u003cli\u003eEnsure that total external field loop resistance, including wire resistance and control valve positioner internal load, does not exceed the 800 Ω maximum threshold.\u003c\/li\u003e\n  \u003cli\u003eVerify that the maximum open circuit voltage stays bounded at 22 V under full operational testing.\u003c\/li\u003e\n  \u003cli\u003eDefine individual channel FAILOPT behaviors (Hold Last Value or Safe Value target) inside the control network manager environment before executing C300 controller logic down-loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617762238648,"sku":"51410070-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PAON01.png?v=1782201388","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-series-c-cc-paon01-51410070-175-analog-output-ao-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}