{"product_id":"honeywell-tc-rpsca2-redundant-power-supply-chassis-adapter-for-c300","title":"Honeywell TC-RPSCA2 Redundant Power Supply Chassis Adapter for C300","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-RPSCA2\u003c\/strong\u003e is a \u003cstrong\u003eredundant power supply chassis adapter\u003c\/strong\u003e designed for the \u003cstrong\u003eExperion C300 controller platform\u003c\/strong\u003e. It enables the integration of redundant power supply modules into the C300 chassis, providing dual power paths for high-availability process control applications where continuous operation is critical.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Chassis adapter for redundant power supply integration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell Experion C300\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Dual power path support\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e C300 chassis-integrated\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Power Path Architecture:\u003c\/strong\u003e Supports two independent power supplies for automatic failover without process interruption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeamless Chassis Integration:\u003c\/strong\u003e Designed specifically for C300 mechanical and electrical specifications, ensuring plug-and-play compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swappable Power Supplies:\u003c\/strong\u003e Allows replacement of a failed power supply while the redundant unit maintains full system operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic Integration:\u003c\/strong\u003e Power status and fault alarms feed directly into the Experion diagnostic system for centralized monitoring.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the TC-RPSCA2 required for all C300 installations?\u003c\/strong\u003e\u003cbr\u003eA: No, it is only required when \u003cstrong\u003eredundant power\u003c\/strong\u003e is specified. Single-power C300 systems use standard non-redundant power entry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supplies are compatible with this adapter?\u003c\/strong\u003e\u003cbr\u003eA: The adapter accepts Honeywell \u003cstrong\u003eredundant power supply modules\u003c\/strong\u003e designed for the C300 platform. Verify specific power module part numbers in the system manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the adapter provide power conditioning?\u003c\/strong\u003e\u003cbr\u003eA: The TC-RPSCA2 provides \u003cstrong\u003emechanical mounting and electrical interconnection\u003c\/strong\u003e. Power conditioning is handled by the installed power supply modules.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstall the TC-RPSCA2 into the \u003cstrong\u003edesignated power adapter slot\u003c\/strong\u003e of the C300 chassis.\u003c\/li\u003e\n  \u003cli\u003eInsert \u003cstrong\u003eredundant power supply modules\u003c\/strong\u003e into the adapter's dual mounting positions.\u003c\/li\u003e\n  \u003cli\u003eConnect \u003cstrong\u003eindependent AC or DC power feeds\u003c\/strong\u003e to each power supply.\u003c\/li\u003e\n  \u003cli\u003eVerify \u003cstrong\u003epower status LEDs\u003c\/strong\u003e on both supplies indicate normal operation.\u003c\/li\u003e\n  \u003cli\u003eTest failover by de-energizing one supply and confirming the second maintains chassis power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailability Requirements:\u003c\/strong\u003e Specify the TC-RPSCA2 for SIL-rated or high-availability processes where power loss is unacceptable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Matching:\u003c\/strong\u003e Always install two \u003cstrong\u003eidentical power supply modules\u003c\/strong\u003e (same part number and firmware revision) for symmetric redundancy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Layout:\u003c\/strong\u003e Ensure adequate clearance behind the C300 chassis for redundant power cabling and ventilation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53978257817784,"sku":"TC-RPSCA2","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-RPSCA2_3_8eca9fe0-c993-470f-bd86-f973a62e66c0.png?v=1787646071","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-tc-rpsca2-redundant-power-supply-chassis-adapter-for-c300","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}