{"product_id":"honeywell-tk-ppd011-51309241-175-c200-series-a-battery-extension-module","title":"Honeywell TK-PPD011 51309241-175 C200 Series A Battery Extension Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTK-PPD011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51309241-175\u003c\/strong\u003e) is a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBattery Extension Module (BEM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS C200 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Its primary role is to preserve critical controller data during unexpected power interruptions by supplying auxiliary backup power to volatile memory. This ensures that control databases, configuration parameters, and runtime logic remain intact throughout a blackout.\u003c\/p\u003e\n\u003cp\u003eUnlike standard power distribution modules, the TK-PPD011 functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata-retention bridge\u003c\/strong\u003e, extending memory protection for up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 hours\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edepending on system load. Installed in a single slot of a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries A chassis\u003c\/strong\u003e, the module continuously monitors battery status and reports health diagnostics to the Experion system. It is an essential safeguard for process industries where loss of control logic could result in extended downtime or unsafe restart conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTK-PPD011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51309241-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Role\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMemory Data Retention \/ Battery Backup Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Series A – C200 \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via chassis backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Current Draw (5 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Current Draw (24 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Retention Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 hours (load dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 × 14.0 × 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated with Experion System Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePreserving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC200 controller memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein facilities with unstable power supplies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtending data retention at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote or unmanned control sites\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsuring reliable recovery after\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eemergency shutdowns\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein chemical and petrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupporting fault-tolerant system designs in regulated industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the battery included with the TK-PPD011?\u003c\/strong\u003e\u003cbr\u003eThe TK-PPD011 is the electronic interface module only. The physical battery pack may be supplied separately or bundled as part of a complete backup power kit, depending on ordering configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module status monitored?\u003c\/strong\u003e\u003cbr\u003eBattery health, charge level, and module status are reported directly to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS diagnostics\u003c\/strong\u003e. Reviewing system alerts on a regular basis (weekly is typical) is recommended to ensure backup readiness.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520950563000,"sku":"TK-PPD011 51309241-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TK-PPD011_51309241-175_5a31002d-e8d8-46c3-9442-a72f0e21c89b.jpg?v=1770019950","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-tk-ppd011-51309241-175-c200-series-a-battery-extension-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}