{"product_id":"ic200acc415-ge-fanuc-emerson-serial-communications-converter","title":"IC200ACC415 | GE Fanuc Emerson Serial Communications Converter","description":"\u003ch3\u003eGE Fanuc IC200ACC415 VersaMax RS-232 to RS-485 Converter Adapter\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200ACC415\u003c\/strong\u003e is an \u003cstrong\u003eRS-232 to RS-485 converter adapter\u003c\/strong\u003e for GE Fanuc VersaMax Micro and Nano PLCs. It converts the PLC's RS-232 serial port to an RS-485 multi-drop bus, enabling communication with up to \u003cstrong\u003e8 slave devices\u003c\/strong\u003e per network (expandable with repeaters). The adapter is \u003cstrong\u003epowered directly by the PLC\u003c\/strong\u003e — no external power supply required.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc \/ Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax Micro \/ Nano\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RS-232 to RS-485 Converter Adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Interface:\u003c\/strong\u003e RS-232 (9-pin D-sub male, from PLC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Interface:\u003c\/strong\u003e RS-485 (15-pin D-sub female, to network)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e Up to 115,200 bps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Powered by host PLC (no external power needed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Slave Devices:\u003c\/strong\u003e 8 per RS-485 network (increasable with repeater)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -10°C to 75°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e MIL-STD 810C, 15G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e TX (transmit) and RX (receive) activity LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3.1\" × 2.4\" × 0.8\" (79 × 61 × 20 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~90g (0.05 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or panel mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e UL (Class 1, Div 2), CUL, CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired cable:\u003c\/strong\u003e IC200CBL500 (RJ-45 to DB9 female, sold separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible PLCs:\u003c\/strong\u003e All VersaMax Micro and Nano PLCs with RS-232 serial port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork topology:\u003c\/strong\u003e RS-485 multi-drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax distance:\u003c\/strong\u003e Up to 1,200 meters with proper cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConnect the \u003cstrong\u003eIC200CBL500\u003c\/strong\u003e cable from the PLC's RJ-45 serial port to the IC200ACC415's 9-pin RS-232 input.\u003c\/li\u003e\n\u003cli\u003eConnect the IC200ACC415's 15-pin RS-485 output to the RS-485 network bus.\u003c\/li\u003e\n\u003cli\u003eMount the adapter on DIN rail or panel using supplied hardware.\u003c\/li\u003e\n\u003cli\u003eVerify \u003cstrong\u003eTX\/RX LEDs\u003c\/strong\u003e blink during data transmission.\u003c\/li\u003e\n\u003cli\u003eConfigure PLC serial port for SNP master\/slave, RTU slave, or Serial I\/O as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does IC200ACC415 need external power?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e It draws power directly from the host PLC's serial port (+5VDC on pin 7, max 100mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cable do I need?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eIC200CBL500\u003c\/strong\u003e (RJ-45 to DB9 female) is required to connect the PLC to the adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many devices can I connect?\u003c\/strong\u003e\u003cbr\u003eA: Up to \u003cstrong\u003e8 slave devices\u003c\/strong\u003e per RS-485 network. Use a repeater to expand beyond 8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum communication distance?\u003c\/strong\u003e\u003cbr\u003eA: Up to \u003cstrong\u003e1,200 meters\u003c\/strong\u003e with proper RS-485 cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will it work with older VersaMax PLCs?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It is compatible with all VersaMax Micro and Nano PLCs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What do the LEDs indicate?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eTX LED\u003c\/strong\u003e = data being transmitted; \u003cstrong\u003eRX LED\u003c\/strong\u003e = data being received. If LEDs stop blinking, check cable connections.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 to RS-485 conversion for Micro\/Nano:\u003c\/strong\u003e IC200ACC415 + IC200CBL500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect RS-485 on 23\/28-point Micro (Port 2):\u003c\/strong\u003e No adapter needed — use DB-15 port directly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB programming:\u003c\/strong\u003e IC200USB001 \/ IC200USB002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial programming cable:\u003c\/strong\u003e IC200CBL001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e PLC model, serial port type, and required cable before ordering\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53720923308216,"sku":"IC200ACC415","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC200ACC201r180.png?v=1783498772","url":"https:\/\/www.globalpetroparts.com\/products\/ic200acc415-ge-fanuc-emerson-serial-communications-converter","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}