{"product_id":"ic200alg326-analog-output-modules-ge-versamax","title":"IC200ALG326 Analog Output Modules GE VersaMax","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG326\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG326\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for multi-channel current signal generation within VersaMax I\/O station platforms. The module interfaces with the station backplane to convert digital data frames into isolated analog current loops across field instruments. It regulates external loop actuators by driving continuous 4-20 mA control pathways derived directly from cyclic processor register updates.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e66.8 mm x 128 mm x 50.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA maximum at 5 VDC from backplane \/ 100 mA maximum at 24 VDC external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended current channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC field excitation voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module supports local I\/O density scaling transitions by accommodating 8 high-resolution current loops on a uniform physical carrier footprint. Integrated logic blocks communicate over the local bus plane without causing capacitive cross-talk or thermal overloading between adjacent hardware channels. Maintained firmware flash compatibility within the VersaMax controller family coordinates deterministic signal update scheduling, suppressing execution latencies during multi-point synchronous scanning sequences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG326 module support extraction or live replacement when the base rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swapping the hardware while backplane power is actively supplied is prohibited. The input lines must be isolated before insertion or extraction to prevent signal line damage or module communication errors.\u003c\/p\u003e\n\u003cp\u003eQ: How does the hardware indicate a loss of the external 24 VDC field excitation supply?\u003c\/p\u003e\n\u003cp\u003eA: A missing or degraded field supply drops the module into an active fault profile, reporting a diagnostic message word to the CPU while the localized LED matrix alters state.\u003c\/p\u003e\n\u003cp\u003eQ: What is the behavior of the current output channels upon a localized loss of backplane logic power?\u003c\/p\u003e\n\u003cp\u003eA: If backplane logic power is interrupted, the output channels default to 0 mA or assume their low-scale fail-safe positions immediately.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit vertically onto a leveled 35 mm DIN-rail base utilizing the compatible VersaMax terminal carrier frame. Retain a minimum open clearance footprint of 50 mm above and below the module ventilation openings to secure proper convective thermal heat sink dissipation. Route all 4-20 mA current signaling lines using dedicated twisted, shielded instrumentation pairs isolated from high-voltage motor or distribution conductors. Secure the field cable shield drains to a single-point panel ground bar to maintain signal resolution and isolate the loops from common-mode electrical noise.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53596267118776,"sku":"IC200ALG326","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC200ALG326_2.jpg?v=1781600053","url":"https:\/\/www.globalpetroparts.com\/products\/ic200alg326-analog-output-modules-ge-versamax","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}