{"product_id":"ic200udr120-ge-fanuc-versamax-micro-20-point-plc","title":"IC200UDR120 | GE Fanuc | VersaMax Micro 20-Point PLC","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UDR120\u003c\/strong\u003e is a \u003cstrong\u003eVersaMax Micro 20-Point PLC\u003c\/strong\u003e with \u003cstrong\u003e12 discrete 24VDC inputs\u003c\/strong\u003e and \u003cstrong\u003e8 relay outputs\u003c\/strong\u003e. It operates from \u003cstrong\u003e120\/240VAC power supply\u003c\/strong\u003e and features high-speed counter inputs, configurable positive\/negative logic, and an integrated CPU with RS-232 serial port. The module supports online programming without stopping the controller.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC200UDR120\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e VersaMax Micro 20-Point PLC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 12 discrete inputs, 24VDC, positive\/negative logic configurable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 8 relay outputs, normally open\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay Rating:\u003c\/strong\u003e 2A @ 24VDC \/ 250VAC (resistive); 0.6A (lamp\/solenoid)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Threshold:\u003c\/strong\u003e ON: 18VDC min; OFF: 5VDC max\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Counter:\u003c\/strong\u003e Up to 100 kHz (4 inputs configurable as HSC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 1–20 ms configurable (regular); 100 µs (HSC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1500V RMS field-to-logic; 500V RMS between groups\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 120\/240VAC (100–240VAC range)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUser Power:\u003c\/strong\u003e 24VDC output up to 435 mA max\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e RS-232 (1 port); optional communication port\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Proficy Machine Edition 5.7 or higher\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Requires IC200ACC414 battery for data retention\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.65 kg (1.43 lbs)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc \/ Emerson Automation Solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e12 inputs configurable as standard or high-speed counter (100 kHz)\u003c\/li\u003e\n  \u003cli\u003e8 relay outputs with 2A rating for industrial loads\u003c\/li\u003e\n  \u003cli\u003e120\/240VAC power supply eliminates need for external DC power\u003c\/li\u003e\n  \u003cli\u003eOnline programming capability — modify logic without stopping\u003c\/li\u003e\n  \u003cli\u003eCompact footprint with expandable I\/O up to 170 points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C (-4°F to 140°F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the IC200UDR120 used for?\u003c\/h4\u003e\n\u003cp\u003eIt is a 20-point compact PLC for small to medium automation tasks, featuring 12 digital inputs and 8 relay outputs with 120\/240VAC power supply.\u003c\/p\u003e\n\n\u003ch4\u003eCan inputs be used as high-speed counters?\u003c\/h4\u003e\n\u003cp\u003eYes — \u003cstrong\u003e4 inputs\u003c\/strong\u003e are configurable as high-speed counters up to \u003cstrong\u003e100 kHz\u003c\/strong\u003e for encoder and pulse signal applications.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between IC200UDR120 and IC200UDR020?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200UDR120\u003c\/strong\u003e has \u003cstrong\u003e12 inputs \/ 8 outputs\u003c\/strong\u003e with \u003cstrong\u003e120\/240VAC\u003c\/strong\u003e power supply. The \u003cstrong\u003eIC200UDR020\u003c\/strong\u003e has \u003cstrong\u003e12 inputs \/ 8 outputs\u003c\/strong\u003e with \u003cstrong\u003e24VDC\u003c\/strong\u003e power supply.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between IC200UDR120 and IC200UDR140?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200UDR120\u003c\/strong\u003e has \u003cstrong\u003e12 inputs \/ 8 outputs\u003c\/strong\u003e. The \u003cstrong\u003eIC200UDR140\u003c\/strong\u003e has \u003cstrong\u003e24 inputs \/ 16 outputs\u003c\/strong\u003e with the same 120\/240VAC power supply.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003ch4\u003eSafety Precautions\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-energize AC power before installation or wiring\u003c\/li\u003e\n  \u003cli\u003eUse proper ESD protection when handling the PLC\u003c\/li\u003e\n  \u003cli\u003eInstall IC200ACC414 battery for data retention\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStep-by-Step Procedure\u003c\/h4\u003e\n\u003col\u003e\n  \u003cli\u003eMount the PLC on DIN rail in the control cabinet\u003c\/li\u003e\n  \u003cli\u003eConnect 120\/240VAC power to the power terminals\u003c\/li\u003e\n  \u003cli\u003eWire field sensors to the 12 input terminals\u003c\/li\u003e\n  \u003cli\u003eWire loads to the 8 relay output terminals\u003c\/li\u003e\n  \u003cli\u003eConnect programming cable to RS-232 port\u003c\/li\u003e\n  \u003cli\u003ePower up and verify status LEDs\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFor DC power supply, select IC200UDR020 instead\u003c\/li\u003e\n  \u003cli\u003eFor 16 outputs, select IC200UDR140 (24 in \/ 16 out)\u003c\/li\u003e\n  \u003cli\u003eFor transistor outputs, select IC200UDD120 (DC outputs)\u003c\/li\u003e\n  \u003cli\u003eEnsure total load current does not exceed 2A per relay output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIC200UDR020 — 12 In \/ 8 Relay Out, 24VDC\u003c\/li\u003e\n  \u003cli\u003eIC200UDR120 — 12 In \/ 8 Relay Out, 120\/240VAC (this part)\u003c\/li\u003e\n  \u003cli\u003eIC200UDR140 — 24 In \/ 16 Relay Out, 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003eIC200UDR164 — 40 In \/ 24 Relay Out, 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003eIC200UDD120 — 12 In \/ 8 DC Out, 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003eIC200ACC414 — Battery for data retention\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53719708860600,"sku":"IC200UDR120","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC200UDR120_1__..png?v=1783498773","url":"https:\/\/www.globalpetroparts.com\/products\/ic200udr120-ge-fanuc-versamax-micro-20-point-plc","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}