{"product_id":"ic200udr140-ge-fanuc-versamax-micro-40-point-plc","title":"IC200UDR140 | GE Fanuc | VersaMax Micro 40-Point PLC","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UDR140\u003c\/strong\u003e is a \u003cstrong\u003eVersaMax Micro 40-Point PLC\u003c\/strong\u003e with \u003cstrong\u003e24 discrete 24VDC inputs\u003c\/strong\u003e and \u003cstrong\u003e16 relay outputs\u003c\/strong\u003e. It operates from \u003cstrong\u003e120\/240VAC\u003c\/strong\u003e and features high-speed counter inputs up to 100 kHz.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC200UDR140\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e VersaMax Micro 40-Point PLC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 24 discrete inputs, 24VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 16 relay outputs, 2A @ 24VDC\/250VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Counter:\u003c\/strong\u003e 4 inputs, up to 100 kHz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUser Power:\u003c\/strong\u003e 24VDC output, 435 mA max\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e RS-232\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Proficy Machine Edition 5.7+\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Requires IC200ACC414 battery\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc \/ Emerson\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e24 inputs configurable as standard or high-speed counter\u003c\/li\u003e\n  \u003cli\u003e16 relay outputs with 2A rating\u003c\/li\u003e\n  \u003cli\u003e120\/240VAC power supply eliminates external DC power\u003c\/li\u003e\n  \u003cli\u003eOnline programming without stopping\u003c\/li\u003e\n  \u003cli\u003eExpandable up to 170 points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the IC200UDR140 used for?\u003c\/h4\u003e\n\u003cp\u003eCompact PLC for small to medium automation with 24 inputs, 16 relay outputs, and 120\/240VAC power.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between IC200UDR140 and IC200UDR040?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIC200UDR140\u003c\/strong\u003e uses 120\/240VAC. \u003cstrong\u003eIC200UDR040\u003c\/strong\u003e uses 24VDC. Both have 24 inputs \/ 16 outputs.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between IC200UDR140 and IC200UDR164?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eIC200UDR140\u003c\/strong\u003e has 24 in \/ 16 out. \u003cstrong\u003eIC200UDR164\u003c\/strong\u003e has 40 in \/ 24 out with same AC power.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003ch4\u003eSafety Precautions\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-energize AC power before installation\u003c\/li\u003e\n  \u003cli\u003eUse ESD protection\u003c\/li\u003e\n  \u003cli\u003eInstall IC200ACC414 battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStep-by-Step\u003c\/h4\u003e\n\u003col\u003e\n  \u003cli\u003eMount on DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnect 120\/240VAC power\u003c\/li\u003e\n  \u003cli\u003eWire 24 inputs and 16 outputs\u003c\/li\u003e\n  \u003cli\u003eConnect RS-232 programming cable\u003c\/li\u003e\n  \u003cli\u003ePower up and verify LEDs\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFor DC power, select IC200UDR040\u003c\/li\u003e\n  \u003cli\u003eFor more I\/O, select IC200UDR164\u003c\/li\u003e\n  \u003cli\u003eFor transistor outputs, select IC200UDD140\u003c\/li\u003e\n  \u003cli\u003eDo not exceed 2A per relay output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIC200UDR040 — 24 In \/ 16 Relay Out, 24VDC\u003c\/li\u003e\n  \u003cli\u003eIC200UDR140 — 24 In \/ 16 Relay Out, 120\/240VAC (this part)\u003c\/li\u003e\n  \u003cli\u003eIC200UDR164 — 40 In \/ 24 Relay Out, 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003eIC200UDD140 — 24 In \/ 16 DC Out, 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003eIC200ACC414 — Battery\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53719803920568,"sku":"IC200UDR140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC200UDR140__r180.png?v=1783498760","url":"https:\/\/www.globalpetroparts.com\/products\/ic200udr140-ge-fanuc-versamax-micro-40-point-plc","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}