{"product_id":"ic660bba026-ge-fanuc-enius-i-o-rtd-input-block","title":"IC660BBA026 GE Fanuc enius I\/O RTD Input Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA026 (IC660BBA026) is a high-precision, 6-channel Resistance Temperature Detector (RTD) input block within the GE Fanuc Genius I\/O family. This intelligent distributed I\/O module interfaces directly with standard RTD sensors to provide accurate temperature data acquisition over the Genius bus. Engineered for thermal monitoring in plastic extrusion, chemical reactors, and large motor bearings, the IC660BBA026 converts low-level resistance signals into digital temperature values. By processing signals at the source, this block eliminates the need for expensive long-run compensated wiring back to a central controller. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-calibrated accuracy and long-term reliability for your process control system.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA026 features advanced signal conditioning and supports multiple RTD types with high resolution.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBA026\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported RTDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum (100, 200, 500 ohm), Nickel (120 ohm), Copper (10 ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 deg C or 0.1 deg F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500V between Genius bus and inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC, 230 VAC, or 24\/48 VDC (Version dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis block accommodates a variety of Platinum, Nickel, and Copper RTDs. Engineers configure the sensor type and temperature scale (Celsius or Fahrenheit) via software, providing a flexible solution for diverse global installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Lead Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BBA026 supports 3-wire RTD configurations, allowing the module to automatically compensate for lead wire resistance. This ensures measurement accuracy even when the block is mounted at a significant distance from the actual sensing point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module monitors each channel for \"Open Sensor,\" \"Short Circuit,\" and \"High\/Low Alarm\" limits. It transmits these diagnostics over the Genius network, allowing operators to identify failed probes before they trigger a process shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the Genius bus, the IC660BBA026 operates as a standalone intelligence unit. It continues to monitor and provide local diagnostics even if communication with the main CPU is momentarily interrupted, maintaining a safe \"Hold Last State\" or \"Go to Zero\" output profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different types of RTDs on the same block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The block typically applies the selected configuration to all six channels. All sensors connected to a single IC660BBA026 must be of the same type (e.g., all Pt 100).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this block require external calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA026 comes factory-calibrated. However, it features self-calibration routines that run periodically to compensate for component aging and ambient temperature drifts, maintaining high accuracy over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the block handle sensor burnout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block detects an open circuit (burnout) and immediately reports a diagnostic fault to the controller. You can program the system to fail-safe by defining how the CPU should interpret the resulting out-of-range data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the terminal base included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA026 consists of the electronic module and the terminal block. Our\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits ship as complete assemblies ready for DIN-rail or panel mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447280033976,"sku":"IC660BBA026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBA026_2.jpg?v=1778231974","url":"https:\/\/www.globalpetroparts.com\/products\/ic660bba026-ge-fanuc-enius-i-o-rtd-input-block","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}