{"product_id":"ic693bem320-ge-fanuc-series-90-30-i-o-link-master-module","title":"IC693BEM320 GE Fanuc Series 90-30 I\/O Link Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eConfigured for distributed I\/O network interfacing in Series 90-30 PLC systems, the \u003cstrong\u003eGE Fanuc IC693BEM320\u003c\/strong\u003e (\u003cstrong\u003eIC693BEM320\u003c\/strong\u003e I\/O Link Master Module) provides direct physical\/electrical execution of high-speed master-slave data transfers via a proprietary serial link.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693BEM320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 mm x 36 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e450 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Link Master Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e250 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Slaves\u003c\/td\u003e\n\u003ctd\u003e16 units per link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eMultidrop Daisy Chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Network Implementation\u003c\/h3\u003e\n\u003cp\u003eThe interface utilizes structured I\/O density scaling mechanisms to parse discrete signals across remote racks without introducing variable latency to the internal logic engine. Deterministic frame structures dictate the transfer cycle, synchronizing decentralized block assemblies with the host processor's backplane scan execution loop. Firmware flash compatibility rules restrict cross-loading between non-contiguous hardware revisions to maintain strict physical link synchronization and ensure correct bus cycle timings are held over the entire physical layer run.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the mechanical insertion constraint regarding hot-swapping the IC693BEM320 module?\u003c\/p\u003e\n\u003cp\u003eA: The IC693BEM320 module does not support hot-swapping. Removal or insertion of the module while the backplane power rail is energized will cause electrical transients capable of corrupting internal circuitry or damaging adjacent modules on the rack.\u003c\/p\u003e\n\u003cp\u003eQ: How is the maximum distance limitation affected by the network cable selection?\u003c\/p\u003e\n\u003cp\u003eA: The transmission architecture adheres to fixed physical line parameters. Utilizing a compliant shielded twisted-pair cable allows the serial bus to achieve its full design distance without signal attenuation, provided no branching or star topologies are introduced into the link.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTerminate power to the target Series 90-30 baseplate prior to sitting the module into its assigned slot.\u003c\/li\u003e\n\u003cli\u003eInsert the module into the baseplate chassis slots using the molded top and bottom alignment guides, ensuring the rear board-edge connector seats fully into the backplane.\u003c\/li\u003e\n\u003cli\u003eSecure the communication cable shielding directly to the local enclosure subpanel ground bar utilizing a low-impedance grounding strap to attenuate high-frequency industrial noise.\u003c\/li\u003e\n\u003cli\u003eVerify that termination resistors are installed exclusively at the absolute physical end-points of the multidrop network loop to control signal reflection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53514690035896,"sku":"IC693BEM320","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693TCM302_1.jpg?v=1779845598","url":"https:\/\/www.globalpetroparts.com\/products\/ic693bem320-ge-fanuc-series-90-30-i-o-link-master-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}