{"product_id":"ic693chs399-ge-fanuc-pacsystems-series-90-30-expansion-baseplate","title":"IC693CHS399 GE Fanuc PACSystems Series 90-30 Expansion Baseplate","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CHS399\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC693CHS399\u003c\/strong\u003e Expansion Baseplate utilized to execute physical and electrical expansion of input\/output subsystems across PACSystems Series 90-30 platforms. This structural backplane provides 5 physical module slots alongside dedicated communication paths to mirror data registers from a primary central processing unit chassis. The unit relies on an external physical expansion cable configuration to establish proper logic synchronization with the master controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC693CHS399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc (PACSystems Series 90-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5-Slot I\/O Expansion Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e13.0 cm x 26.4 cm x 4.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eNone (Passive Backplane Bus Routing Component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMaximum I\/O Slots\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e5 Module Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSystem Input Power\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eSupplied via locally attached Series 90-30 Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eCable Interface\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eBuilt-in 25-pin D-sub Expansion Port Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eMounting Format\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePanel mount or standard DIN-rail configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Bus Communications\u003c\/h3\u003e\n\u003cp\u003eThis passive frame assembly facilitates immediate I\/O density scaling adjustments without requiring additional processor licenses or firmware modifications. The parallel backplane bus communication velocity handles synchronous bit scanning across all 5 logic module slots simultaneously. High physical trace clearances shield logic tracks from sudden input voltage steps on adjacent high-power relay cards. Full hardware firmware flash compatibility exists for all plugged Series 90-30 discrete, analog, and specialty communication modules tracking data loops through this infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 5-slot expansion chassis be hot-swapped or extended while the primary CPU baseplate is operational?\u003c\/p\u003e\n\u003cp\u003eA: No. Connecting or disconnecting the 25-pin D-sub expansion cable under electrical tension can cause communication bus failure, trigger a system parity fault inside the host processor, and halt ongoing factory automation processes.\u003c\/p\u003e\n\u003cp\u003eQ: Is a separate, standalone power supply required to operationalize this specific expansion rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Every IC693CHS399 chassis requires a dedicated Series 90-30 power supply module plugged directly into the leftmost slot position to supply the internal 5 VDC and 24 VDC logic rails for the localized I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Orientation\u003c\/strong\u003e: Mount the baseplate horizontally on a flat vertical surface to facilitate regular convection cooling through the slotted module enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connection Stability\u003c\/strong\u003e: Secure the 25-pin expansion cable plug with the integrated thumbscrews on the D-sub interface port to prevent mechanical extraction during persistent low-frequency factory vibrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding\u003c\/strong\u003e: Establish a low-impedance connection from the baseplate ground terminal screw directly to the main mounting panel or protective electrical enclosure earth bar to enforce accurate noise suppression limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53512207368376,"sku":"IC693CHS399","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693CHS393_1.jpg?v=1779786399","url":"https:\/\/www.globalpetroparts.com\/products\/ic693chs399-ge-fanuc-pacsystems-series-90-30-expansion-baseplate","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}