{"product_id":"ic693mdl231-series-90-30-ac-input-module-ge-fanuc","title":"IC693MDL231 Series 90-30 AC Input Module GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL231\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC693MDL231\u003c\/strong\u003e Input Module utilized to execute discrete electrical signal sensing across Series 90-30 programmable logic controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 mm x 36 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 mA at 5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 Inputs (1 group of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-state Voltage\u003c\/td\u003e\n\u003ctd\u003e74 VAC Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-state Voltage\u003c\/td\u003e\n\u003ctd\u003e20 VAC Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC field-to-logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Data Sync and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 8-point discrete architecture interfaces directly with internal logic circuits via the parallel backplane bus communication velocity pathways built into the rack chassis. This layout dictates predictable I\/O density scaling profiles, isolating thermal radiation across adjacent slots during full concurrent multi-point state changes. Input registers update cyclically within designated hardware scan routines, ensuring complete firmware flash compatibility rules align individual channel states with host controller memories without adding communication latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is hot-swapping the IC693MDL231 module permitted while the rack baseplate is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The parallel backplane interface rails do not feature sequenced pin physical layout lengths. Live module insertion or extraction is strictly prohibited as it can generate transient voltage vectors capable of causing catastrophic failure to the internal logic components.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal electronic circuit filter transient voltage variations on the AC input lines?\u003c\/p\u003e\n\u003cp\u003eA: The input circuitry implements independent hardware resistor-capacitor (RC) filters coupled with opto-couplers on each channel. These components introduce a deterministic delay on input state changes to filter out line noise, harmonic deviations, and contact bounce before updating the I\/O table.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTerminate all power paths feeding the local Series 90-30 backplane assembly prior to mechanical insertion of the module.\u003c\/li\u003e\n\u003cli\u003eSlide the module housing straight into the designated single-slot card guides and press firmly backward until the upper and lower plastic retention clips snap secure over the chassis edge.\u003c\/li\u003e\n\u003cli\u003eWire the 120 VAC neutral reference line to the common return terminal on the physical terminal block, ensuring solid retention under terminal screws.\u003c\/li\u003e\n\u003cli\u003eRoute all high-voltage AC field conductors through independent wiring ducts segregated from low-voltage communication paths by a minimum distance of 30 cm to mitigate electromagnetic induction loop interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53514697310392,"sku":"IC693MDL231","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693MDL231_1_1.jpg?v=1779846851","url":"https:\/\/www.globalpetroparts.com\/products\/ic693mdl231-series-90-30-ac-input-module-ge-fanuc","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}