{"product_id":"ic694mdl260-ge-fanuc-120-vac-discrete-input-module","title":"IC694MDL260 | GE Fanuc | 120 VAC Discrete Input Module","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL260 is a 120 VAC discrete input module for the PACSystems RX3i platform. It provides 32 input points organized in four isolated groups of eight points each. Isolation is implemented between groups, while inputs within each group share a common reference.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC694MDL260\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 120 VAC Grouped Discrete Input Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible System:\u003c\/strong\u003e PACSystems RX3i (requires CPU firmware version 3.50 or later)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 32 (four isolated groups of 8 inputs)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 120 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0 to 132 VAC, 47–63 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 7.0 mA typical per point at rated voltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 220 mA at 5 VDC (all inputs ON)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e 70 to 132 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e 0 to 20 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e 5 mA minimum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOff-State Current:\u003c\/strong\u003e 2.5 mA maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Filter Time:\u003c\/strong\u003e Configurable from 20 ms to 2540 ms in 20 ms increments (set by CPU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Dependent on filter setting (0–4 AC cycles)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 264 VAC continuous \/ 1500 VAC for 1 minute (field to backplane and group to group)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHardware Integration \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e 32 green LEDs (one per input) plus terminal block presence LED\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Requires IC694TBB032, IC694TBB132, IC694TBS032 or IC694TBS132 (ordered separately)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Terminal block presence reported to RX3i CPU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot Swap Capability:\u003c\/strong\u003e Supported in RX3i Universal Backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify RX3i CPU firmware is version 3.50 or higher.\u003c\/li\u003e\n  \u003cli\u003ePower down the rack or use hot-swap procedure if supported.\u003c\/li\u003e\n  \u003cli\u003eInsert the module into any I\/O slot, ensuring proper alignment with card guides.\u003c\/li\u003e\n  \u003cli\u003eSecure the module and install the appropriate terminal block.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring observing group commons.\u003c\/li\u003e\n  \u003cli\u003eApply power and configure input filter times via the programming software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSelect IC694MDL260 for high-density 120 VAC applications requiring grouped isolation.\u003c\/li\u003e\n  \u003cli\u003eFor fully isolated 120 VAC inputs, consider IC694MDL250 (16 points).\u003c\/li\u003e\n  \u003cli\u003eFor 240 VAC requirements, refer to IC694MDL231.\u003c\/li\u003e\n  \u003cli\u003eEnsure sufficient backplane power capacity for the 220 mA draw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eIs the IC694MDL260 compatible with Series 90-30 CPUs?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eNo. It is designed exclusively for PACSystems RX3i and requires firmware version 3.50 or later.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eWhat terminal blocks are compatible?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eIC694TBB032, IC694TBB132, IC694TBS032, or IC694TBS132.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eAre the input filter times configurable?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eYes. Filter times are configurable from 20 ms to 2540 ms in 20 ms increments via the CPU configuration.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53673839362232,"sku":"IC694MDL260","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC694MDL260.png?v=1782792403","url":"https:\/\/www.globalpetroparts.com\/products\/ic694mdl260-ge-fanuc-120-vac-discrete-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}