{"product_id":"ic695alg112-ge-fanuc-isolated-analog-module-12-channel","title":"IC695ALG112 | GE Fanuc Isolated Analog Module | 12-Channel","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe GE IC695ALG112 is a 12-channel isolated analog input module for PACSystems RX3i Universal Backplanes. Each channel is individually isolated and supports multiple voltage and current ranges. The module uses a 16-bit ADC and provides configurable filtering, scaling, alarms, and diagnostic reporting. It is fully software-configurable and supports hot-swapping.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e IC695ALG112\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Isolated Analog Input Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Compatibility:\u003c\/strong\u003e RX3i Universal Backplane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 12 isolated input channels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Ranges (Voltage):\u003c\/strong\u003e ±10 V, 0–10 V, ±5 V, 0–5 V, 1–5 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Ranges (Current):\u003c\/strong\u003e 0–20 mA, 4–20 mA, ±20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit ADC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Impedance (Voltage):\u003c\/strong\u003e 500 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Resistance (Current):\u003c\/strong\u003e 250 Ω ±1%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e 1 second maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Format:\u003c\/strong\u003e IEEE 32-bit floating point or 16-bit integer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilter Options:\u003c\/strong\u003e 8 Hz, 12 Hz, 16 Hz, 40 Hz, 250 Hz, 1000 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 490 mA @ 5 V; 310 mA @ 3.3 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 4.89 W maximum (all channels at 20 mA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e ±35 VDC continuous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e ±35 mA continuous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Requirement:\u003c\/strong\u003e Single slot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Requirement:\u003c\/strong\u003e IC694TBB032 \/ IC694TBB132 \/ IC694TBS032 \/ IC694TBS132\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFunctional Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndividually isolated analog input channels.\u003c\/li\u003e\n  \u003cli\u003eSoftware-configurable ranges, scaling, and offsets.\u003c\/li\u003e\n  \u003cli\u003eHigh, low, high-high, and low-low alarm thresholds per channel.\u003c\/li\u003e\n  \u003cli\u003eRate-of-change alarms for both positive and negative transitions.\u003c\/li\u003e\n  \u003cli\u003eDiagnostic fault reporting and point-level fault contacts.\u003c\/li\u003e\n  \u003cli\u003eTerminal block insertion\/removal detection.\u003c\/li\u003e\n  \u003cli\u003eHot-swappable module design.\u003c\/li\u003e\n  \u003cli\u003eFlash memory for firmware upgrades.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstall the module in an RX3i Universal Backplane slot.\u003c\/li\u003e\n  \u003cli\u003eUse only the specified terminal blocks; extended versions required for shielded wiring.\u003c\/li\u003e\n  \u003cli\u003eEnsure wiring matches the configured input type (voltage or current).\u003c\/li\u003e\n  \u003cli\u003eMaintain environmental conditions within RX3i system specifications.\u003c\/li\u003e\n  \u003cli\u003eVerify CPU firmware version is 5.0 or later.\u003c\/li\u003e\n  \u003cli\u003eObserve isolation and grounding practices to minimize noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes IC695ALG112 support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eYes. The module can be inserted or removed from a powered backplane.\u003c\/li\u003e\n\n  \u003cli\u003e\n\u003cstrong\u003eAre all channels isolated?\u003c\/strong\u003e\u003cbr\u003eYes. All 12 channels are individually isolated.\u003c\/li\u003e\n\n  \u003cli\u003e\n\u003cstrong\u003eCan the module detect open circuits?\u003c\/strong\u003e\u003cbr\u003eYes. Open-circuit detection is supported for voltage and 4–20 mA inputs.\u003c\/li\u003e\n\n  \u003cli\u003e\n\u003cstrong\u003eIs a terminal block included?\u003c\/strong\u003e\u003cbr\u003eNo. Terminal blocks must be ordered separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53673791094968,"sku":"IC695ALG112","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695ALG112.png?v=1782791870","url":"https:\/\/www.globalpetroparts.com\/products\/ic695alg112-ge-fanuc-isolated-analog-module-12-channel","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}