{"product_id":"ic697cmm711-ge-fanuc-series-90-70-communications-coprocessor-module","title":"IC697CMM711 | GE Fanuc Series 90-70 Communications Coprocessor Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Communications Coprocessor (CMM) for the Series 90-70 PLC platform. This module offloads heavy serial communication tasks from the main CPU, providing two independent serial ports for interfacing with HMIs, third-party devices, and supervisory systems. It supports a wide array of industrial protocols, including SNP\/SNP-X, CCM, and Modbus RTU. We provide this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring peak signal integrity and hardware longevity for your mission-critical legacy infrastructure.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 MHz 80C186\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo (2) 25-pin D-shell Female Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Standards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232, RS-422, and RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSNP\/SNP-X (Master\/Slave), CCM (Master\/Slave\/Peer), Modbus RTU (Slave Only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speeds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 Kbps or 19.2 Kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 Amps from +5V Backplane Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, PORT 1, and PORT 2 LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManual Controls\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Re-initialize Pushbutton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries 90-70 CPU Baseplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized CPU Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC697CMM711 utilizes its own 80C186 microprocessor to manage serial framing and protocol handshaking. This dedicated processing prevents serial data traffic from increasing the PLC scan time, maintaining deterministic logic execution even during heavy data polling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports simultaneous operation of different protocols on its two ports. For example, you can configure Port 1 for SNP communication to a local HMI while Port 2 operates as a Modbus RTU slave for a SCADA system, eliminating the need for separate gateway hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Hardware Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 25-pin D-shell connectors provide secure, industrial-grade physical connections. These ports support RS-422 and RS-485 differential signaling, which effectively rejects common-mode noise in long-distance cable runs across electrically noisy factory floors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Resynchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated \"Restart\" pushbutton allows maintenance personnel to re-initialize communication channels without cycling power to the entire PLC rack. This feature drastically reduces downtime during the commissioning of new serial device networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC697CMM711 act as a Modbus Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC697CMM711 supports Modbus RTU in Slave mode only. If your application requires the Series 90-70 to initiate commands to third-party Modbus devices, you should consider a Programmable Coprocessor Module (PCM) or a newer RX7i upgrade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a battery for configuration storage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC697CMM711 does not require an internal battery. It receives its configuration parameters directly from the CPU during the system power-up sequence, ensuring the module remains maintenance-free for its entire service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the three LED indicators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"OK\" LED confirms the module passed its internal power-up self-test. The \"PORT 1\" and \"PORT 2\" LEDs flash to indicate active data transmission or reception on the respective channels, providing immediate visual confirmation of network health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or \"pulled\" unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We guarantee this IC697CMM711 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock. This is critical for communication modules, as used serial ports often suffer from driver chip degradation or damaged connector pins that cause intermittent \"Time-Out\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53082234716344,"sku":"IC697CMM711","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC697CMM711.jpg?v=1774261931","url":"https:\/\/www.globalpetroparts.com\/products\/ic697cmm711-ge-fanuc-series-90-70-communications-coprocessor-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}