{"product_id":"is200staih2a-mark-vi-simplex-analog-input-terminal-board-ge","title":"IS200STAIH2A Mark VI Simplex Analog Input Terminal Board GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200STAIH2A operates as a Simplex Analog Input Terminal Board within the Speedtronic Mark VI turbine control system architecture. This 100% brand new, authentic factory-original component provides the physical termination points for external field sensors, landing vital analog signals directly into the control cabinet. Baseload power generation plants, heavy petrochemical processing facilities, and gas pipeline compressor stations utilize this card to accept critical standard 4-20 mA current loops and voltage inputs from temperature transmitters, pressure transducers, and flow meters. The board loops these field signals into the matching I\/O processor pack via high-density ribbon cabling. By maintaining a clean, physically organized electrical interface at the cabinet boundary, this terminal block stabilizes raw sensor data feeds and prevents erratic signal disruptions from compromising complex turbine control loops.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alpha-numeric engineering code structure embedded within the IS200STAIH2A product number communicates specific hardware configurations designated by General Electric:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS200:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresents the standard physical printed circuit board (PCB) baseline design layout utilized across the Mark VI control chassis family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSTAI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the specific functional application as a Simplex Technology Analog Input terminal block assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClassifies the group two hardware variation layer, designating specific terminal block counts, jumper layouts, and circuit configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHighlights the certified initial factory revision layer, denoting the base component design verified for rugged industrial application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200STAIH2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSimplex Analog Input Terminal Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New original factory stock\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts up to 10 analog inputs (supporting 4-20 mA current loops)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy-duty barrier stack terminal blocks with screw clamp locking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoop Power Distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides dedicated 24 V DC transmitter power supply lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCabling Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnforces dual high-density connector plugs for direct I\/O pack bridging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 65 deg Celsius (optimized for localized marshalling cabinets)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe physical build and localized layout design of the IS200STAIH2A resolve common terminal wiring degradation and electromagnetic noise invasion challenges found on harsh turbine decks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Onboard Surge and RF Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLong field wiring loops act like antennas, catching severe radio frequency interference (RFI) and electromagnetic fields from high-power generator buses. This terminal board integrates independent resistor-capacitor (RC) filtering networks and metal oxide varistors on every input channel. This shielding system shunts high-frequency electrical noise and transient surges to chassis ground before the spikes reach sensitive I\/O converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Barrier Terminal Block Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibrating turbine enclosures cause loose wire terminations over time, resulting in erratic signal dropping. This module uses heavy-duty, industrial-grade screw-clamp barrier terminal blocks that lock fields wires into place physically. This design prevents terminal loosening from constant low-frequency floor vibrations and facilitates straightforward testing using standard multimeter probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnboard Transmitter Power Fusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField sensor short circuits can blow out internal cabinet components if left unchecked. This board incorporates individual, self-resetting current limiting devices (PTCs) or dedicated fuses on each transmitter power loop. When a field transmitter shorts out, the localized protection isolates that specific circuit instantly, keeping the remaining analog input channels active and preventing complete system shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this IS200STAIH2A terminal board arrive inside factory-sealed packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this product in 100% brand new, original factory-sealed condition. The board remains secured inside its original General Electric anti-static shielding enclosure, complete with authentic factory labels, tracking barcodes, and original inspection markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this board for a redundantly configured TMR Mark VI control system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"STAI\" configuration designates a Simplex board option, meaning it supports single-channel I\/O paths rather than Triple Modular Redundant (TMR) cross-voting architectures. TMR layouts require specialized \"TTAI\" or matching redundant terminal blocks to split signals safely across three independent I\/O packs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the critical steps when landing field wiring onto this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must strip the field wires cleanly to the factory-specified length and torque the terminal screws precisely to the rated limits. Do not run high-voltage AC lines in the same conduit as your low-voltage analog wires, and ensure you tie the outer cable shield braids to the proper cabinet ground bar rather than floating the shields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53491840123064,"sku":"IS200STAIH2A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200STAIH2A_1_1.jpg?v=1779355158","url":"https:\/\/www.globalpetroparts.com\/products\/is200staih2a-mark-vi-simplex-analog-input-terminal-board-ge","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}