{"product_id":"is200tbais1ced-ge-mark-vi-analog-input-terminal-board","title":"IS200TBAIS1CED GE Mark VI Analog Input Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200TBAIS1CED operates as a high-performance analog input terminal board within the General Electric Mark VI Speedtronic turbine control platform. This hardware component links field transmitters directly to the central control rack layer. The module accommodates up to 10 analog inputs, accepting standard 4-20 mA current loops, ±5 V DC, and ±10 V DC voltage spans. It distributes localized DC excitation power to external loops and filters high-frequency electrical disturbances before routing the process variables to core processing blocks. This card ensures precise, isolated signal transmission for critical governor loops, fuel systems, and balance-of-plant parameters.\u003c\/p\u003e\n\u003cp\u003eWe distribute this high-integrity hardware asset exclusively as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure standard operational parameters and zero material tracking flaws inside your system cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBAIS1CED packages barrier-style terminal blocks, passive filtering traces, and high-density ribbon cable plugs onto a ruggedized baseplate. The table below outlines the definitive electrical, physical, and environmental parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200TBAIS1CED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Group\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTBAI (Analog Input Terminal Board Assembly)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Coding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1CED (Designates specific block configuration and full coating group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Analog Input Channels (Supports 2-wire, 3-wire, or 4-wire configurations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Formats\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA current loops, ±5 V DC, ±10 V DC voltage spans\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated 24 V DC loop power distribution with current limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC isolation barrier separating field loops from logic circuits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to +140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing relative humidity parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Attenuation Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated passive resistor-capacitor (RC) filters line every input track on the board. This structural architecture blocks high-frequency electromagnetic interference (EMI) and line noise coming from long field cable runs, which prevents signal jitter inside active turbine control algorithms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalized Loop Power Safeguards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board provides integrated 24 V DC power tracks to feed active field transmitters. If a field switch shorts out during maintenance, the built-in current-limiting circuit isolates that single channel immediately, preserving power to the remaining 9 operational input paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRigid Barrier-Style Screw Terminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade physical barrier strips separate each terminal screw point. This mechanical geometry prevents loose wire strands from shifting over to touch adjacent lines, neutralizing the risk of accidental short-circuits during field routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSevere Environment Chemical Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA durable, factory-applied conformal coating seals the copper traces and surface joints. This insulation barrier stops moisture tracking, salt-air oxidation, and conductive dust from inducing localized short-circuits across terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific upgrade path does the 'S1CED' revision provide over older TBAI variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S1CED\" suffix defines a fully updated revision level that utilizes high-performance component groups and a comprehensive conformal coating layer. This variation manages trace heat more effectively and resists signal crosstalk better than early \"TBAI\" design iterations while remaining 100% backward functional and physical compatible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I test individual input loop current parameters directly on the board terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. The board layout includes built-in diagnostic test points along each input path. Field technicians can measure loop voltages and active currents with a standard digital multimeter without unseating the field wires or interrupting active process data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this board support hot-swapping procedures for the driving I\/O cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: While the terminal blocks hold field wiring permanently, you must turn off rack power before pulling the internal logic ribbon cables. Disconnecting active data links while under power can disrupt parallel bus communication and trigger an immediate turbine trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I connect both loop-powered and self-powered transmitters to this module simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. The multi-terminal layout for each channel provides separate connections for 24 V DC supply power, return lines, and shield ground paths. This lets you wire self-powered 4-wire instruments and loop-powered 2-wire sensors to the exact same block profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53477585748152,"sku":"IS200TBAIS1CED","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200TBAIS1CED_1_1.jpg?v=1779088296","url":"https:\/\/www.globalpetroparts.com\/products\/is200tbais1ced-ge-mark-vi-analog-input-terminal-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}