{"product_id":"is200tvibh2bbb-ge-speedtronic-mark-vi-vibration-terminal-board","title":"IS200TVIBH2BBB GE Speedtronic Mark VI Vibration Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200TVIBH2BBB operates as a dedicated Vibration Terminal Board within the Speedtronic Mark VI turbine control and protection platform. This heavy-duty hardware component provides the direct physical termination interface for critical machinery health sensors, including eddy current proximity probes, seismic velocity pick-ups, and accelerometers. It accepts raw dynamic signals from rotating turbine shafts, processing and routing the telemetry directly to the VVIB core processor board. Installing this Brand New, original GE terminal board eliminates signal attenuation and ensures accurate asset protection monitoring to prevent catastrophic mechanical turbine failures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below details the electrical interfaces, structural dimensions, and environmental constraints of the IS200TVIBH2BBB terminal board:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification \/ Operational Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200TVIBH2BBB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpeedtronic Mark VI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Terminal Board (TVIB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity probes, Accelerometers, Seismic velocity sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple independent high-frequency vibration inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBarrier-type screw terminal blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCabling Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual high-density plugs for ribbon cable linking to VME rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +55°C (+32°F to +131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IS200TVIBH2BBB addresses critical signal processing and field environment challenges inherent to high-speed turbomachinery infrastructure:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Noise Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board architecture incorporates dedicated shield termination points for every channel, grounding high-frequency electromagnetic interference (EMI) away from weak sensor signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnboard Sensor Power Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated current-limiting circuits supply independent, isolated power to external proximity transducers, preventing a short circuit on one field sensor from disabling adjacent monitoring channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Multi-Core Bus Bridging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-plug header layout permits clean ribbon cable routing directly to the internal Mark VI VME card cage, maintaining complete trace path integrity across simplex or TMR processor setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Terminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade barrier screw strips secure heavy-gauge field wiring permanently, preventing wire back-out or intermittent contact issues caused by continuous turbine deck vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific architectural variant does the \"H2BBB\" suffix indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"H2BBB\" code denotes the precise hardware revision layer, geometric component placement profile, and backward-compatibility baseline. This specific variation matches standardized Mark VI cabinets and links seamlessly with the VVIB processor board. Always verify your master cabinet layout parameters via the ControlST or Toolbox application software prior to live system loop integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IS200TVIBH2BBB require external calibration tools during field installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TVIB board acts as a passive termination layer and does not contain adjustable potentiometers or field-programmable chips. The internal Mark VI VVIB processor board handles all scaling, signal configuration, and threshold calibration digitally via the central HMI console interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan technicians connect 2-wire and 3-wire vibration sensors to this board simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The terminal arrangement provides independent assignment paths for signal, common, and power connections. Field engineers can wire both 2-wire constant-current accelerometers and standard 3-wire proximity probe systems to designated terminal groups by adjusting the channel configuration matrix within the software environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53482059595960,"sku":"IS200TVIBH2BBB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200TVIBH2BBB_2_1.jpg?v=1779184286","url":"https:\/\/www.globalpetroparts.com\/products\/is200tvibh2bbb-ge-speedtronic-mark-vi-vibration-terminal-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}