{"product_id":"is200vsvoh1b-ge-mark-vi-servo-control-board","title":"IS200VSVOH1B GE Mark VI Servo Control Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200VSVOH1B (IS200VSVOH1B) functions as a high-performance Servo Control Board within the Speedtronic Mark VI turbine control platform. This 100% brand new, authentic factory-original module provides the core interface that drives electro-hydraulic servo valves and processes positional feedback from Linear Variable Differential Transformers (LVDTs). Heavy power plants, gas turbine pipeline stations, and steam turbine facilities utilize this board to govern fuel control valves, guide vanes, and steam control valves. The board modulates precise current outputs to position the servo coils exactly according to main controller calculations. By maintaining continuous closed-loop position monitoring, this card stabilizes fuel combustion profiles, guarantees prompt throttle responses, and safeguards heavy rotating machinery from unsafe fuel surges.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alpha-numeric engineering codes structured into the IS200VSVOH1B product number define specific functional and design attributes designated by General Electric:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS200:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes the foundational printed circuit board (PCB) size and form factor layout for standard Mark VI control racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVSVO:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the core functional configuration as a specialized Valve Servo Control board module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the group one hardware assembly layer, defining the active onboard channel count and connector pinouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes the second-generation factory-certified engineering revision, featuring upgraded component tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200VSVOH1B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eValve Servo Control Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eServo Output Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControls up to 2 electro-hydraulic servo valve coils\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLVDT Feedback Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 4 LVDT or RVDT position sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelivers bi-directional outputs up to +\/- 10mA or +\/- 40mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExcitation Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenerates 3.2 kHz localized LVDT excitation voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg Celsius (inside standard rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe circuit architecture and hardware layout of the IS200VSVOH1B resolve common servo loop drift and high-noise interference problems found on industrial turbine decks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Dynamic Current Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTemperature shifts inside local control rooms can cause standard analog outputs to drift. This board integrates automated null-current calibration circuits that balance the output stage constantly. This active adjustment prevents servo position drift, ensuring tight control of fuel valve openings even during extended operating runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated LVDT Excitation Sources:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-talk between adjacent position sensors can cause erratic valve tracking. This card utilizes separate, isolated AC excitation loops for each LVDT channel. This electrical segregation stops channel-to-channel noise interference, maintaining flat, stable position readouts over long field wire runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Based High-Speed Trip Relay Links:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen an emergency stop occurs, waiting for software processors to command a shutdown risks turbine overspeed. The board contains direct, hard-wired trip input paths that instantly force the servo outputs to maximum negative current. This hardware override cuts off fuel or steam valves within milliseconds, bypassing software lag to shield the plant from overspeed damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this IS200VSVOH1B board arrive with original factory seals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We deliver this module in 100% brand new, original factory condition. The card sits untouched inside its original anti-static box, complete with matching General Electric serial tracking tags and barcode certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200VSVOH1B board accept inputs from 2-wire or 3-wire LVDTs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board natively supports standard 3-wire and 4-wire LVDT or RVDT position feedback devices. You configure the precise sensor wiring parameters and excitation voltages via your system's control drawing layout and software configuration parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the required steps when replacing an active servo control board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must safely isolate the turbine fuel or steam hydraulics before servicing the rack. Power down the VME control rack completely, slide out the old board, insert the new module, and then verify the specific jump-pin positions match your site drawings. Always recalibrate the valve LVDT stroke limits using the system software before restarting the turbine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53491806077112,"sku":"IS200VSVOH1B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200VSVOH1BDC_1_1_f30ce58f-cf0a-4dee-a67c-34d176d284ed.jpg?v=1779353252","url":"https:\/\/www.globalpetroparts.com\/products\/is200vsvoh1b-ge-mark-vi-servo-control-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}