{"product_id":"is200vvibh1c-ge-mark-vi-vibration-monitor-board","title":"IS200VVIBH1C GE Mark VI Vibration Monitor Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200VVIBH1C operates as the primary Vibration Monitor Board within the Speedtronic Mark VI turbine control ecosystem. This 100% brand new, authentic factory-original card interfaces directly with proximity probes, seismic sensors, and accelerometers mounted on heavy rotating machinery. Combined-cycle power generation plants, heavy industrial compression stations, and marine propulsion facilities rely on this board to track real-time shaft vibration, axial position, and casing eccentricity. The module converts raw analog sensor signals into precise digital metrics for the VME master controller. By providing continuous, high-fidelity monitoring of mechanical displacements, this board identifies shaft misalignments, prevents catastrophic rotor contact, and triggers immediate automated safety trips during critical imbalance events.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alpha-numeric engineering nomenclature used within the IS200VVIBH1C product code outlines specific design parameters specified by General Electric:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS200:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefines the standardized physical printed circuit board (PCB) footprint and form factor utilized across the Mark VI control rack system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVVIB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the core functional application group as a specialized Vibration and Proximity Monitor interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the group one hardware configuration, designating the available channel density and input signal voltage scaling profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHighlights the certified third-generation factory revision level, indicating optimized onboard electrical component selection for continuous service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200VVIBH1C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMachinery Vibration Monitor Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New original factory stock\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Eddy Current Proximity Probes, Accelerometers, and Velomitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcesses multiple independent high-speed vibration and position inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Processing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrates onboard analog-to-digital converters (ADCs) with digital filtering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard parallel communication link via Mark VI rack slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg Celsius (mounted within standard cooling racks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe hardware layout and input stage circuitry of the IS200VVIBH1C solve chronic measurement drift and signal degradation challenges on high-vibration turbine decks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Onboard Anti-Aliasing Filters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-frequency electrical noise from nearby generator fields can distort analog vibration waveforms. This card passes all incoming sensor signals through dedicated hardware anti-aliasing filters before digitization. This filtering suppresses high-frequency artifacts completely, ensuring true-to-life tracking of sub-synchronous and synchronous shaft vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Negative Bias Voltage Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity probes require stable negative DC bias voltages to measure gaps accurately, but fluctuating field temperatures can compromise power stability. This module incorporates precise onboard negative power regulators that stabilize the sensor excitation loop. This feature eliminates temperature-induced measurement drift, preserving exact axial position data over long-term operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDedicated Hardware Peak-to-Peak Detectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelying purely on software loops to catch instantaneous physical shaft deflections risks missing rapid spike failures. This board utilizes hazards-free, hardware-based peak-to-peak voltage tracking circuits that scan the waveform continuously. This independent monitoring architecture updates the system instantly, allowing the turbine trip relays to activate ahead of catastrophic mechanical breakdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this IS200VVIBH1C monitor board arrive in original factory-sealed condition?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this board as 100% brand new, authentic factory stock. The item remains sealed inside its original General Electric anti-static packaging, displaying matching factory serial numbers, inspection stamps, and official tracking barcodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200VVIBH1C handle direct connections to Bently Nevada proximity systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The board accepts industry-standard negative voltage inputs from Bently Nevada 3300 XL and related proximity probe transducer systems. You configure the precise scale factors (such as 200 mV\/mil) and sensor types through the GE Toolbox software configuration layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the vital steps to follow when inserting this replacement board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must switch off all electrical power to the targeted VME rack before insertion to avoid damaging the high-density backplane connection pins. Slide the card smoothly along the rack guides until the connectors seat firmly, tighten the front faceplate retaining screws to establish solid chassis ground, and then upload the matching hardware configuration parameters via your engineering software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53491834290360,"sku":"IS200VVIBH1C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200VVIBH1C_1_1.jpg?v=1779354746","url":"https:\/\/www.globalpetroparts.com\/products\/is200vvibh1c-ge-mark-vi-vibration-monitor-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}