{"product_id":"is220ydoas1aj-ge-mark-vie-discrete-output-i-o-pack-module","title":"IS220YDOAS1AJ | GE | Mark VIe Discrete Output I\/O Pack Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS220YDOAS1AJ functions as a high-performance discrete output I\/O pack within the General Electric Mark VIe Speedtronic turbine control architecture. This compact, processor-driven device mounts directly onto compatible relay output terminal boards to bridge the central control network and external field actuators. It receives digital logic commands over dual redundant industrial Ethernet IONet ports, processes the state changes through an onboard microcontroller, and drives the underlying terminal board hardware to switch solenoids, motor starters, and interposing relays. By executing real-time output loop-back monitoring and diagnostic calculations at the local terminal layer, this module ensures precise control over critical power generation tripping and sequence circuits.\u003c\/p\u003e\n\u003cp\u003eWe supply this technical automation component exclusively as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee clean internal circuit pathways and maximum service longevity inside your control panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS220YDOAS1AJ encloses dual RJ-45 Ethernet transceivers, localized logic processors, and a high-density 37-pin interface socket within a ruggedized protective housing. The table below outlines the core electrical, network, and environmental operational parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220YDOAS1AJ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe Speedtronic System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Group\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYDOA (Discrete Output Input\/Output Pack Assembly)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Revision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1AJ (Designates specific component baseline and cooling profile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 10\/100 Base-TX RJ-45 copper Ethernet ports for IONet redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 V DC nominal (Accepts 18.5 V DC to 32.0 V DC operational range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A DC maximum configuration load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Diagnostic Matrix\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-panel infrared and LED status indicators (Power, Link, Fault)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Mating Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 37-pin D-sub plug matching standard TRLS\/TLYS terminal boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing operating envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port IONet Network Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware integrates two fully independent RJ-45 Ethernet interfaces to communicate across separate IONet paths. If a network switch or cable suffers an unexpected physical break, the module switches to the secondary network layer instantly without dropping outputs or interrupting active processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Loop-Back Status Validation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal processor reads the actual electrical status of the underlying relay coils continuously. If an external line open-circuit occurs or a relay contact fails to respond to a trip command, the pack identifies the discrepancy within milliseconds and transmits a precise diagnostic alert to the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Terminal Standoff Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe structural casing includes built-in securing bolts that thread directly into terminal board standoffs. This rigid mechanical layout eliminates loose component vibration, guarantees perfect alignment for the 37-pin interface pins, and removes the need for custom backplate bracket drilling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFanless Thermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe outer chassis acts as a structural heat sink, shifting internal thermal loads away from critical processing chips through natural air convection. This fanless design keeps dust and metallic particulate matter out of the sensitive logic circuitry, which prevents localized short-circuits in heavy industrial milling or processing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What separates the 'S1AJ' version of this discrete output pack from older 'S1A' models?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The \"S1AJ\" revision introduces upgraded Ethernet transceivers and a refined internal power conditioning layout. This hardware update reduces standby current consumption, improves protection against high-frequency electromagnetic noise across the IONet cables, and retains full physical and software compatibility with standard TRLS and TRLY terminal structures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I hot-swap the IS220YDOAS1AJ module while the turbine control system is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes. In redundant or Triple Modular Redundant (TMR) terminal board layouts, you can unbolt and swap out a faulted IS220YDOAS1AJ pack while the control panel remains under power. The parallel packs on the terminal board maintain output control during the replacement window, avoiding unexpected process downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do the front-panel indicator lights assist with immediate panel troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The faceplate features distinct LEDs that display Power, IONet Link Activity, and Fault status. A solid green light confirms valid internal voltage regulation, flashing green indicates healthy network synchronization, and a solid amber or red light signals an internal hardware exception or a loop-back verification failure, streamlining fault localization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53477535088824,"sku":"IS220YDOAS1AJ","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS220YDOAS1AJ_3_1.jpg?v=1779087794","url":"https:\/\/www.globalpetroparts.com\/products\/is220ydoas1aj-ge-mark-vie-discrete-output-i-o-pack-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}