{"product_id":"is230snhrh2a-ge-mark-vie-hart-analog-input-output-board","title":"IS230SNHRH2A | GE Mark VIe | HART Analog Input Output Board","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003eHigh-Fidelity Analog Integration with HART Intelligence\u003c\/h3\u003e\n\u003cp\u003eThe GE\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(also identified by the alternate part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNHRH2A\u003c\/strong\u003e) is a sophisticated analog input\/output terminal board designed for the Mark VIe and Mark VIeS turbine control platforms. This board serves as the primary interface between the control system and high-precision field instruments, providing both signal acquisition and command output. Uniquely equipped with HART (Highway Addressable Remote Transducer) protocol support, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the control system to communicate digitally with smart transmitters, enabling advanced remote configuration, asset management, and deep diagnostic insights without interrupting the 4–20 mA analog signal.\u003c\/p\u003e\n\u003ch3\u003ePrecision Signal Conversion and System Stability\u003c\/h3\u003e\n\u003cp\u003eIn mission-critical turbine automation, signal integrity is paramount. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates the conversion of field variables such as pressure, temperature, and flow into deterministic data for the Mark VIe controllers. It features an ultra-low drift architecture with an accuracy rating of ±0.1% of full scale. Beyond simple I\/O, the board incorporates self-calibration routines and comprehensive fault detection, including open-loop and short-circuit monitoring. This ensures that any degradation in field wiring or sensor performance is flagged immediately, preventing unplanned trips and maintaining the operational stability of gas and steam turbines.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe technical parameters below represent the operational standards for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNHRH2A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Energy (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIS200SHRAH2A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIS230SNHRH2A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe \/ Mark VIeS Turbine Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART-enabled Analog Input\/Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypically 8 Channels (4-20 mA, 0-5V, 0-10V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypically 4 Channels (4-20 mA, 0-20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART Communication (Smart Instrument Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (±5%); Max Current ~2.8 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-level fault detection \u0026amp; HART status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e165 mm × 102 mm × 229 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e900 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52528906207416,"sku":"IS200SHRAH2A（IS230SNHRH2A)","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/201.jpg?v=1770197129","url":"https:\/\/www.globalpetroparts.com\/products\/is230snhrh2a-ge-mark-vie-hart-analog-input-output-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}