{"product_id":"is230snrlh2a-ge-fanuc-mark-vie-servo-node-relay-card","title":"IS230SNRLH2A | GE Fanuc | Mark VIe Servo Node Relay Card","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003eHigh-Integrity Relay Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe GE\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNRLH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNRLH2A\u003c\/strong\u003e) functions as a critical output interface within the Mark VIe distributed control system (DCS). This module is engineered to bridge the gap between low-level control logic and high-power field devices, such as solenoid valves, motor starters, and hydraulic actuators. By utilizing mechanical relay isolation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNRLH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects the sensitive control electronics from back-EMF and electrical noise common in heavy industrial environments.\u003c\/p\u003e\n\u003cp\u003eAs part of the Mark VIe I\/O subsystem, the module communicates over the proprietary IONet, an Ethernet-based deterministic network. The unit is specifically configured for DIN rail mounting, allowing for flexible installation within control cabinets or remote I\/O enclosures. Its dual-redundant communication paths ensure that control signals remain active even if one network branch is compromised, which is vital for gas and steam turbine safety.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table summarizes the operational and hardware parameters for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS230SNRLH2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelay module.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIS230SNRLH2A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Mark VIe \/ Mark VIeS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectromechanical Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 16 Channels (configuration dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A at 24 V DC \/ 48 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 V DC Nominal (via backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 W to 15 W Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation (Channel-to-Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 100Base-TX Ethernet (IONet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52525827129528,"sku":"IS230SNRLH2A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/89._8e4cbcf5-4104-4544-95cc-bdefa71f6a22.jpg?v=1770104463","url":"https:\/\/www.globalpetroparts.com\/products\/is230snrlh2a-ge-fanuc-mark-vie-servo-node-relay-card","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}