{"product_id":"kj1501x1-bc4-emerson-deltav-system-power-supply-module","title":"KJ1501X1-BC4 | Emerson DeltaV System Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ1501X1-BC4\u003c\/strong\u003e is a \u003cstrong\u003eSystem Dual DC Power Supply\u003c\/strong\u003e for the DeltaV™ M-Series distributed control system. It accepts either 12 VDC or 24 VDC bulk input and delivers regulated DC outputs to power controllers, I\/O interfaces, and internal system electronics in hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ1501X1-BC4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e 13P0063X052\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e System Dual DC Power Supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 12 VDC at 14.8 A  OR  24 VDC at 6.1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Rating:\u003c\/strong\u003e 12 VDC at 13 A (12 V input); 12 VDC at 8 A (24 V input); +5.1 VDC at 2.0 A; +3.4 VDC at 2.0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombined Output Power (+5.1 V \u0026amp; +3.4 V):\u003c\/strong\u003e 10.2 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 – 550 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Safety Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −40 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 10 g, ½ sine wave for 11 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 % – 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e ISA-S71.04-1985 Class G3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX II 3G Ex nA nC IIC Gc; Nemko; Class I Div. 2 Groups A,B,C,D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input flexibility (12 V or 24 V) reduces spare-part inventory\u003c\/li\u003e\n\u003cli\u003eLoad-sharing capability enables redundant power configurations\u003c\/li\u003e\n\u003cli\u003eInternal power bus on carrier removes need for external cabling\u003c\/li\u003e\n\u003cli\u003eImmediate power-fail notification to the controller\u003c\/li\u003e\n\u003cli\u003eSystem and field power circuits are fully isolated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I power this supply from a 24 VDC plant bulk source?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The KJ1501X1-BC4 accepts either 12 VDC or 24 VDC input and automatically regulates the output bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: No. Power must be de-energized before removing or inserting the supply to prevent arcing and bus damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between BC4 and BB1\/BA1?\u003c\/strong\u003e\u003cbr\u003eA: The BC4 is a dual DC power supply with similar form factor to the BB1\/BA1 series. Verify your carrier power budget and keying before selecting.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the Power\/Controller carrier on a T-type DIN rail.\u003c\/li\u003e\n\u003cli\u003eConnect bulk 12 VDC or 24 VDC to the carrier field terminals.\u003c\/li\u003e\n\u003cli\u003eAlign the KJ1501X1-BC4 with the carrier slot and press firmly until seated.\u003c\/li\u003e\n\u003cli\u003eDo \u003cstrong\u003enot\u003c\/strong\u003e remove or insert while system power is energized.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse KJ1501X1-BC4 when your bulk power is 12 VDC or 24 VDC and you need a dual-input supply for M-series controllers.\u003c\/li\u003e\n\u003cli\u003eFor dual-redundant power architectures, install two supplies on a redundant-capable carrier.\u003c\/li\u003e\n\u003cli\u003eConfirm carrier width (2-wide vs. 4-wide) before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53852346122424,"sku":"KJ1501X1-BC4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/KJ1501X1-BC4.png?v=1785734932","url":"https:\/\/www.globalpetroparts.com\/products\/kj1501x1-bc4-emerson-deltav-system-power-supply-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}