{"product_id":"kj2005x1-ba2-emerson-deltav-mx-controller-module","title":"KJ2005X1-BA2 | Emerson DeltaV | MX Controller Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ2005X1-BA2\u003c\/strong\u003e (also known as \u003cstrong\u003eVE3007\u003c\/strong\u003e) is the \u003cstrong\u003eDeltaV™ MX Controller\u003c\/strong\u003e, delivering \u003cstrong\u003e2× the control capacity\u003c\/strong\u003e of the MD Plus and MQ controllers. It supports up to \u003cstrong\u003e1,500 Device Signal Tags (DSTs)\u003c\/strong\u003e and \u003cstrong\u003e96 MB user memory\u003c\/strong\u003e, making it ideal for complex, multi-loop process optimization. The MX Controller supports 1:1 redundancy and is backward-compatible with existing DeltaV configurations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ2005X1-BA2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlternate Model:\u003c\/strong\u003e VE3007\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e DeltaV MX Controller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUser Memory:\u003c\/strong\u003e 96 MB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDST Capacity:\u003c\/strong\u003e 50–1,500 Device Signal Tags (scalable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Bus Power:\u003c\/strong\u003e +5 VDC at 1.4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 5.0 W typical, 7.0 W maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Protection:\u003c\/strong\u003e 3.0 A non-replaceable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Network:\u003c\/strong\u003e Dual 100 Mbps full-duplex Ethernet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental \u0026amp; Safety Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 10g, ½ sine wave for 11 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e ISA-S71.04-1985 Class G3 with conformal coating\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX EEx nA IIC T4, FM Class I Div. 2 Groups A–D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e FM19ATEX0173U, IECEx FMG 19.0019U, FM21UKEX0017U\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eInstall the MX Controller on a \u003cstrong\u003e2-wide Power\/Controller Carrier\u003c\/strong\u003e compatible with DeltaV S-Series.\u003c\/li\u003e\n  \u003cli\u003eConnect primary and redundant Ethernet cables to the dual RJ-45 ports.\u003c\/li\u003e\n  \u003cli\u003eEnsure the system power supply can deliver +5 VDC at 1.4 A per controller.\u003c\/li\u003e\n  \u003cli\u003eFor redundancy, install a second MX Controller in the adjacent slot and pair them in DeltaV Explorer.\u003c\/li\u003e\n  \u003cli\u003eDownload existing configuration automatically; no manual reconfiguration is required when replacing MD\/MQ controllers.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What is the advantage of MX over MQ controllers?\u003c\/strong\u003e\u003cbr\u003eA: The MX offers double the DST capacity (up to 1,500 tags) and 96 MB user memory versus the MQ, enabling more complex control strategies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Can I upgrade from MQ to MX online?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the MX can replace an MQ controller without changing hardware design or configuration, supporting online upgrades.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Does it support HART pass-through?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the MX Controller supports HART pass-through for live device diagnostics via DeltaV AMS Device Manager.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Is it compatible with legacy PROVOX or RS3 systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports migration from PROVOX and RS3 systems with up to 750 real I\/O signals per controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSelect the MX Controller for medium to large process units requiring high tag counts and advanced control algorithms.\u003c\/li\u003e\n  \u003cli\u003eAlways deploy redundant pairs for critical control loops to minimize unplanned downtime.\u003c\/li\u003e\n  \u003cli\u003eVerify DeltaV software version is v10.3 or later to ensure full MX Controller feature support.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53768202485944,"sku":"KJ2005X1-BA2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/KJ2005X1-BA2.png?v=1784095420","url":"https:\/\/www.globalpetroparts.com\/products\/kj2005x1-ba2-emerson-deltav-mx-controller-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}