{"product_id":"kj3206x1-bk1-emerson-deltav-di-8-channel-24vdc-isolated","title":"KJ3206X1-BK1 | Emerson DeltaV DI 8-Channel 24VDC Isolated","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ3206X1-BK1\u003c\/strong\u003e is an \u003cstrong\u003e8-Channel, 24 VDC Isolated Digital Input (DI) Card\u003c\/strong\u003e for the DeltaV™ S-Series distributed control system. It provides isolated discrete input monitoring for industrial automation, certified for hazardous-area installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ3206X1-BK1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e S-Series DI 8-Channel 24 VDC Isolated Card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 isolated digital inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Bus Power:\u003c\/strong\u003e 12 VDC at 100 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Circuit Power:\u003c\/strong\u003e 24 VDC at 6 mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 310 – 550 g (varies by source)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Safety Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −40 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 10 g, ½ sine wave for 11 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 % – 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e ISA-S71.04-1985 Class G3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX II 3G Ex ec IIC Gc; FM19ATEX0173U; IECEx FMG 19.0019U; Class I Div. 2 Groups A,B,C,D; Class I Zone 2 AEx\/Ex ec IIC Gc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight individually isolated inputs for enhanced signal integrity\u003c\/li\u003e\n\u003cli\u003eHigh-speed data acquisition optimized for industrial automation\u003c\/li\u003e\n\u003cli\u003eRugged environmental protection for extreme conditions\u003c\/li\u003e\n\u003cli\u003eSeamless integration with DeltaV S-Series automation setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the input current per channel?\u003c\/strong\u003e\u003cbr\u003eA: Each channel draws 6 mA from the 24 VDC field circuit power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: Field power must be removed before module removal or insertion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix this with analog I\/O on the same carrier?\u003c\/strong\u003e\u003cbr\u003eA: Yes, provided the carrier supports S-Series modules and total local bus current is not exceeded.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the card into an available S-Series carrier slot.\u003c\/li\u003e\n\u003cli\u003eConnect 24 VDC discrete field wiring to the terminal block.\u003c\/li\u003e\n\u003cli\u003eVerify input status LEDs for each channel via DeltaV diagnostics.\u003c\/li\u003e\n\u003cli\u003eEnsure proper shield grounding to prevent EMI interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose KJ3206X1-BK1 when you need 8 isolated 24 VDC digital inputs for DeltaV S-Series.\u003c\/li\u003e\n\u003cli\u003eCalculate total local bus current (100 mA for this card) across all carrier slots.\u003c\/li\u003e\n\u003cli\u003eFor non-isolated or higher-density DI requirements, verify alternative S-Series cards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53852347433144,"sku":"KJ3206X1-BK1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/KJ3206X1-BK1_2.png?v=1785480416","url":"https:\/\/www.globalpetroparts.com\/products\/kj3206x1-bk1-emerson-deltav-di-8-channel-24vdc-isolated","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}