{"product_id":"kj4006x1-bl1-emerson-deltav-8-channel-terminal-block-2-4-wire","title":"KJ4006X1-BL1 | Emerson DeltaV | 8-Channel Terminal Block 2\/4 wire","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ3203X1-BK1\u003c\/strong\u003e is an S-Series \u003cstrong\u003eDigital Input (DI) Module\u003c\/strong\u003e featuring \u003cstrong\u003e32 channels of 24 VDC dry contact inputs\u003c\/strong\u003e. Designed for the DeltaV™ distributed control system, it provides high-density discrete signal acquisition for process monitoring and control applications. The module supports redundant configurations and is certified for hazardous area deployment.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ3203X1-BK1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlternate Part Number:\u003c\/strong\u003e 12P4694X032\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e S-Series DI 32-Channel 24 VDC Dry Contact Card\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 32 dry contact inputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e ~2 mA per channel (5 mA field circuit per channel)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 10–30 VDC (ON), \u0026lt;5 VDC (OFF)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Bus Power:\u003c\/strong\u003e 12 VDC at 75 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBussed Field Power:\u003c\/strong\u003e 24 VDC at 150 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Key:\u003c\/strong\u003e B3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg (300g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental \u0026amp; Hazardous Area Ratings\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 10g, ½ sine wave for 11 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e ISA-S71.04-1985 Class G3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e II 3G Ex ec IIC Gc, Class I Div. 2 Groups A–D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e FM19ATEX0173U, IECEx FMG 19.0019U, FM21UKEX0017U\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eSet the terminal block rotary key to position \u003cstrong\u003eB3\u003c\/strong\u003e before mating with the I\/O card.\u003c\/li\u003e\n  \u003cli\u003eRemove all field power (local bus and bussed field power) before inserting or removing the card.\u003c\/li\u003e\n  \u003cli\u003eMount the card in an 8-wide I\/O carrier in any of the 64 available slots.\u003c\/li\u003e\n  \u003cli\u003eConnect dry contact field devices to the terminal block, ensuring proper polarity.\u003c\/li\u003e\n  \u003cli\u003eVerify LED indicators (Power, Error, Active) confirm normal operation via DeltaV Explorer.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What is a dry contact input?\u003c\/strong\u003e\u003cbr\u003eA: A dry contact input detects the open\/closed state of a mechanical switch or relay contact without external voltage applied by the field device.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Can this module be used in a redundant configuration?\u003c\/strong\u003e\u003cbr\u003eA: Yes, S-Series cards support redundant I\/O configurations for increased system availability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What terminal block should I use?\u003c\/strong\u003e\u003cbr\u003eA: Use the matching S-Series terminal block with key position B3 (e.g., KJ4006X1-BF1 for 32-channel discrete).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Is the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: Only in non-hazardous areas with proper procedures; hazardous areas require power removal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUse KJ3203X1-BK1 for high-density discrete input applications such as limit switches, pushbuttons, and relay status monitoring.\u003c\/li\u003e\n  \u003cli\u003eEnsure field devices are true dry contacts; wet contacts may require isolated input modules (e.g., KJ3206X1-BA1).\u003c\/li\u003e\n  \u003cli\u003ePlan power budget: 12 VDC local bus at 75 mA plus 24 VDC field power at 150 mA per card.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53768212906168,"sku":"KJ4006X1-BL1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/KJ4006X1-BL1r180.png?v=1784095356","url":"https:\/\/www.globalpetroparts.com\/products\/kj4006x1-bl1-emerson-deltav-8-channel-terminal-block-2-4-wire","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}