{"product_id":"lcn-input-output-interface-board-51109394-100-honeywell","title":"LCN Input\/Output Interface Board 51109394-100 Honeywell","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51109394-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized Input\/Output (I\/O) adapter board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell TDC 3000 and Experion PKS distributed control systems (DCS)\u003c\/strong\u003e. It functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLocal Control Network (LCN) node interface\u003c\/strong\u003e, enabling high-speed communication between the processor and the system backplane. The board is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDual Node configurations\u003c\/strong\u003e, providing critical synchronization for process control and operator station connectivity.\u003c\/p\u003e\n\u003cp\u003eDesigned to meet\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial-grade reliability standards\u003c\/strong\u003e, the 51109394-100 ensures that process variables and control commands are transmitted with minimal latency. It is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elegacy and transition-era Honeywell chassis\u003c\/strong\u003e, offering a dependable solution for maintaining communication integrity in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical, power generation, and large-scale manufacturing environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51109394-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System (DCS) \/ I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCN Node Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData routing and interface management for LCN communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell DCS Card Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed internal bus synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCB Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-layer industrial-grade laminate with corrosion-resistant plating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-pluggable (depending on system configuration and safety protocols)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowered via the backplane assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNode Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring real-time data consistency between redundant processor nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBridging I\/O processor logic with the Local Control Network (LCN) for system-wide monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReliable replacement for aging TDC 3000 I\/O nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Upgrades:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFacilitates integration of legacy I\/O clusters into modern Experion PKS environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 51109394-100 compatible with CE-compliant systems?\u003c\/strong\u003e\u003cbr\u003eThis board is generally associated with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elegacy non-CE (Common Enclosure) or transitional architectures\u003c\/strong\u003e. Always verify the chassis type (5-slot or 10-slot) and version before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board manage Analog or Digital I\/O signals directly?\u003c\/strong\u003e\u003cbr\u003eNo. The 51109394-100 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication and interface board\u003c\/strong\u003e. Actual field signal conditioning is performed by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated AI, AO, DI, or DO modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnected to the system.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52521175875768,"sku":"51109394-100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51109394-100_845110b7-8c03-446b-9ba5-f60bcece4bcb.jpg?v=1770024182","url":"https:\/\/www.globalpetroparts.com\/products\/lcn-input-output-interface-board-51109394-100-honeywell","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}