{"product_id":"mark-v-drive-control-board-ds200sdccg4a-ge","title":"Mark V Drive Control Board DS200SDCCG4A GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200SDCCG4A (DS200SDCCG4A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary intelligence hub for General Electric's DC2000 and AC2000 drive systems. As a critical component of the Mark V Speedtronic series, this board executes high-speed computational logic for motor control, power conversion, and system diagnostics. We supply this board as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original equipment. It integrates three distinct microprocessors to manage drive-related functions, including motor regulation and user interface communication. By centralizing control logic, the DS200SDCCG4A ensures deterministic performance in heavy industrial sectors such as steel manufacturing, paper milling, and power generation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200SDCCG4A features a sophisticated multi-layered hardware architecture designed for real-time control.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Microprocessor (Drive, Motor, and Co-processor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Drives\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE DC2000 and AC2000 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 Serial Port (maintenance\/diagnostics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density ribbon cable connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Power Bus via backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard GE Full-Height Drive Card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200SDCCG4A solves complex integration challenges through superior hardware design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComputational Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes a Master Drive Control Processor and a Motor Control Processor. This separation prevents logic bottlenecks during high-frequency torque adjustments, ensuring stable motor operation even under fluctuating loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineers designed the SDCCG4A with high-grade industrial shielding. This suppresses electromagnetic interference, allowing the board to operate reliably near high-voltage switchgear and heavy-duty motor cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Diagnostic Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard LEDs provide immediate status indication for LAN activity, processor health, and fault conditions. This allows technicians to bypass complex software debugging for routine hardware verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its high processing power, the board maintains a slim profile that fits standard Mark V rack slots, simplifying the upgrade path for aging drive cabinets with limited clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Maintenance FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the DS200SDCCG4A interchangeable with earlier G1 or G2 versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe G4A revision typically offers backward compatibility; however, you must verify the firmware EPROM versions. Always transfer the specific EPROMs from your old board to the new board to maintain existing software parameters and drive tuning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The board draws its logic-level power through the backplane connectors once seated in the drive rack. Ensure the drive system is fully de-energized before insertion to avoid arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the board handle communication with external PLCs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt communicates via the ARCNET (Local Area Network) protocol through the drive’s internal bus. For local maintenance, you can utilize the onboard RS232 port to connect a PC running GE’s configuration software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"A\" suffix in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"A\" indicates a specific functional revision level. GE G4A boards incorporate the latest circuit refinements to improve thermal stability and signal processing compared to legacy \"G1\" iterations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53459840532664,"sku":"DS200SDCCG4A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200SDCCG5A_2_1.jpg?v=1778663223","url":"https:\/\/www.globalpetroparts.com\/products\/mark-v-drive-control-board-ds200sdccg4a-ge","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}