{"product_id":"mvi56e-61850s-prosoft-server-communication-module","title":"MVI56E-61850S | Prosoft Server Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-61850S\u003c\/strong\u003e is an \u003cstrong\u003eIEC 61850 Server Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. It transforms a ControlLogix PAC into a fully compliant \u003cstrong\u003eIEC 61850 Intelligent Electronic Device (IED)\u003c\/strong\u003e, enabling seamless integration with utility SCADA, energy management systems (EMS), and substation automation networks. Supporting \u003cstrong\u003eMMS, GOOSE, and ACSI services\u003c\/strong\u003e, this module allows non-intelligent electrical equipment (transformers, breakers, switchgear) to present standardized IEC 61850 data models to upper-level systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56E-61850S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e IEC 61850 Server Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56E Enhanced for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e IEC 61850-8-1 MMS, GOOSE, ACSI, SCL (ICD\/CID\/SCD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45 (optional SFP fiber)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical Nodes:\u003c\/strong\u003e GGIO, LLN0, MMXU, CSWI, PTOC, XCBR, and 40+ standard nodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOOSE Messages:\u003c\/strong\u003e Send\/receive up to 256 GOOSE messages with VLAN priority\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Capacity:\u003c\/strong\u003e 10,000 16-bit registers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e SNTP \/ IEEE 1588 PTP (SOE resolution ≤ 1 ms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB), IEDScout, SCL Manager\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (-XT variant: -25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 61850 Ed. 2, CE, UL, cULus, RoHS, IEC 61000-4 Level 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIED Virtualization:\u003c\/strong\u003e Presents ControlLogix data as standard IEC 61850 logical nodes — no relay programming required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance GOOSE:\u003c\/strong\u003e 256 concurrent GOOSE messages with VLAN tagging and MAC filtering for protection signaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation-Grade Time Sync:\u003c\/strong\u003e IEEE 1588 PTP support delivers ≤ 1 ms SOE resolution for fault analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMassive Data Capacity:\u003c\/strong\u003e 10,000-point register space covers entire 110 kV substation data requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Architecture:\u003c\/strong\u003e Backplane expansion supports up to 4 modules for 500 kV hub-station applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-Click Diagnostics:\u003c\/strong\u003e Built-in web server displays IED tree, GOOSE counters, and MMS session status\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSubstation automation retrofitting legacy transformers and breakers into IEC 61850 SCADA\u003c\/li\u003e\n\u003cli\u003eRenewable energy farm integration (wind\/solar) with utility IEC 61850 control centers\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution with ControlLogix monitoring and IEC 61850 EMS reporting\u003c\/li\u003e\n\u003cli\u003eMicrogrid control with battery energy storage systems (BESS) communicating via IEC 61850\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the ControlLogix rack before installing the MVI56E-61850S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available 1756 slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to the substation station bus or process bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module using the ProSoft AOP and import generated UDTs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical Node Configuration:\u003c\/strong\u003e In PCB, map ControlLogix tags to IEC 61850 logical nodes (GGIO, MMXU, etc.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOOSE Setup:\u003c\/strong\u003e Configure publisher\/subscriber datasets, VLAN IDs, and AppIDs per substation design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCL Export:\u003c\/strong\u003e Generate ICD\/CID files from PCB and provide to system integrator for SCD compilation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Sync:\u003c\/strong\u003e Configure PTP grandmaster IP or SNTP server for event timestamping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e Enable IP whitelisting and SSL\/TLS encryption per NERC CIP requirements\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module act as an IEC 61850 client?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003eMVI56E-61850S\u003c\/strong\u003e operates as an \u003cstrong\u003eIEC 61850 Server (IED)\u003c\/strong\u003e. For Client\/SCADA master functionality, consult ProSoft for alternative solutions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support IEC 61850-9-2 LE sampled values?\u003c\/strong\u003e\u003cbr\u003e\nA: The MVI56E-61850S primarily supports \u003cstrong\u003eMMS and GOOSE\u003c\/strong\u003e. For \u003cstrong\u003eSampled Values (SV)\u003c\/strong\u003e process bus applications, verify specific firmware support or consult ProSoft.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many logical nodes can I configure per module?\u003c\/strong\u003e\u003cbr\u003e\nA: The module supports \u003cstrong\u003e40+ standard logical node types\u003c\/strong\u003e with a total data capacity of \u003cstrong\u003e10,000 registers\u003c\/strong\u003e, typically sufficient for a complete 110 kV bay.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the failover time for redundant configurations?\u003c\/strong\u003e\u003cbr\u003e\nA: When deployed in dual-module redundant configurations with proper switch configuration, failover times are \u003cstrong\u003e\u0026lt; 50 ms\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWork with your substation design engineer early to define logical node assignments and LNType selections\u003c\/li\u003e\n\u003cli\u003eRequest ICD files from all IED vendors before commissioning to compile the SCD file\u003c\/li\u003e\n\u003cli\u003eUse PTP (not SNTP) if your protection engineer requires SOE resolution under 4 ms\u003c\/li\u003e\n\u003cli\u003ePlan for 4-module expansion if designing a 500 kV hub station with multiple bays\u003c\/li\u003e\n\u003cli\u003eOrder the -XT variant for outdoor installations or substations without HVAC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776593551544,"sku":"MVI56E-61850S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETCR_3.png?v=1784182786","url":"https:\/\/www.globalpetroparts.com\/products\/mvi56e-61850s-prosoft-server-communication-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}