{"product_id":"new-woodward-5437-080-netcon-field-terminal-module","title":"New Woodward 5437-080 NetCon Field Terminal Module","description":"\u003ch3\u003eWoodward 5437-080 NetCon Field Terminal Module (FTM)\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 5437-080\u003c\/strong\u003e is a \u003cstrong\u003eField Terminal Module (FTM)\u003c\/strong\u003e for NetCon governor and digital control systems. It serves as the interface between field wiring and NetCon I\/O modules, providing secure termination points, signal conditioning, and protection for control system inputs and outputs.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5437-080\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Field Terminal Module (FTM)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e NetCon Governor \/ NetCon 5000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Woodward, Inc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Field wiring termination and signal interface for NetCon I\/O\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e Medium density, typically 256–2048 point range (system-dependent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStructure:\u003c\/strong\u003e Modular, hard PLC processor-based\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Control room \/ panel installation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (typical)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e NetCon 5000, 501, 503, 509 series controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Conditioning:\u003c\/strong\u003e Provides filtering and isolation between field devices and sensitive I\/O electronics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e Hot-swappable design allows module replacement without rewiring field cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Termination:\u003c\/strong\u003e Compact design maximizes I\/O density in control panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Withstands vibration, temperature extremes, and electrical noise in power generation environments.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNetCon governor system field wiring interface\u003c\/li\u003e\n  \u003cli\u003eGas turbine and steam turbine I\/O termination\u003c\/li\u003e\n  \u003cli\u003eCompressor and pump control panels\u003c\/li\u003e\n  \u003cli\u003ePower generation plant automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 5437-080 include active electronics?\u003c\/strong\u003e\u003cbr\u003e\nA: The 5437-080 is primarily a \u003cstrong\u003epassive termination module\u003c\/strong\u003e with some signal conditioning. Active processing occurs in the associated I\/O modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use 5437-080 with 2301 or 505 governors?\u003c\/strong\u003e\u003cbr\u003e\nA: The 5437-080 is designed for \u003cstrong\u003eNetCon systems\u003c\/strong\u003e. For 2301 or 505 governors, use their respective terminal assemblies.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount the 5437-080 FTM in the control panel adjacent to the NetCon chassis.\u003c\/li\u003e\n  \u003cli\u003eConnect field wires to the terminal block per the wiring schedule.\u003c\/li\u003e\n  \u003cli\u003eLink FTM to NetCon I\/O modules via internal ribbon cables or backplane connectors.\u003c\/li\u003e\n  \u003cli\u003eVerify all shield grounds are properly bonded.\u003c\/li\u003e\n  \u003cli\u003ePower on and verify I\/O channel functionality through NetCon diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Density:\u003c\/strong\u003e Confirm your application requires medium-density termination (256–2048 points) vs. high-density alternatives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Verify FTM supports your mix of analog, discrete, and relay signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReplacement:\u003c\/strong\u003e If 5437-080 is obsolete, inquire about Woodward's current FTM replacement recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53763818029240,"sku":"5437-080","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5437-080_2.png?v=1783925652","url":"https:\/\/www.globalpetroparts.com\/products\/new-woodward-5437-080-netcon-field-terminal-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}