{"product_id":"prosoft-mvi56-afc-advanced-flow-computer-module","title":"Prosoft MVI56-AFC Advanced Flow Computer Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-AFC\u003c\/strong\u003e is an \u003cstrong\u003eAdvanced Flow Computer Module\u003c\/strong\u003e designed for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. It installs directly into a 1756 ControlLogix chassis, providing \u003cstrong\u003eAGA, GPA, ISO, and API-compliant\u003c\/strong\u003e flow calculations for custody transfer and process measurement applications. This module eliminates the need for external flow computers by performing all metering calculations — including orifice, turbine, ultrasonic, and Coriolis meter types — directly on the ControlLogix backplane.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56-AFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Advanced Flow Computer Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56 for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Types:\u003c\/strong\u003e Orifice, nozzle, venturi, turbine, ultrasonic, Coriolis, vortex, PD meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculation Standards:\u003c\/strong\u003e AGA-3, AGA-7, AGA-8, AGA-9, AGA-11, GPA 2172, ISO 5167, API MPMS Chapter 11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun Capacity:\u003c\/strong\u003e Up to 8 meter runs per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB) with flow wizard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Interface:\u003c\/strong\u003e Direct tag mapping to ControlLogix controller tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarming:\u003c\/strong\u003e Configurable high\/low alarms, flow direction, maintenance flags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Flow Computing:\u003c\/strong\u003e Performs all flow calculations on the ControlLogix backplane — no external flow computer required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Standard Compliance:\u003c\/strong\u003e Supports AGA, GPA, ISO, and API standards for global custody transfer acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Meter Types:\u003c\/strong\u003e Handles orifice, turbine, ultrasonic, Coriolis, and other primary devices in one module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Run Support:\u003c\/strong\u003e Up to 8 independent meter runs reduce hardware count in multi-stream applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Data:\u003c\/strong\u003e Flow rates, totals, averages, and diagnostic data available as native ControlLogix tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudit Trail:\u003c\/strong\u003e Event logging and alarm history for regulatory compliance and custody transfer auditing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas custody transfer metering stations\u003c\/li\u003e\n\u003cli\u003eRefinery product flow measurement and allocation\u003c\/li\u003e\n\u003cli\u003eChemical plant reactor feed flow control\u003c\/li\u003e\n\u003cli\u003eWater district billing and consumption monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF ControlLogix rack power before installing the MVI56-AFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available slot on the 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module to your project using the ProSoft AOP or generic module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Launch ProSoft Configuration Builder and create a new flow computer project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Configuration:\u003c\/strong\u003e Select meter type (orifice, turbine, etc.), pipe diameter, fluid properties, and calculation standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Mapping:\u003c\/strong\u003e Map differential pressure, temperature, and pressure transmitter signals to module input tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Setup:\u003c\/strong\u003e Configure high\/low flow alarms, maintenance flags, and event logging parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownload \u0026amp; Verify:\u003c\/strong\u003e Download configuration to the module and verify flow calculations against hand calculations\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module replace a traditional flow computer?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eYes\u003c\/strong\u003e, the MVI56-AFC performs all flow calculation functions internally, eliminating the need for separate flow computers in most applications while maintaining custody transfer compliance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What transmitter signals does it require?\u003c\/strong\u003e\u003cbr\u003e\nA: The module requires \u003cstrong\u003edifferential pressure, static pressure, and temperature\u003c\/strong\u003e inputs (typically 4–20 mA) mapped through ControlLogix analog input modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for LNG or cryogenic applications?\u003c\/strong\u003e\u003cbr\u003e\nA: The module supports \u003cstrong\u003eAGA-8\u003c\/strong\u003e and \u003cstrong\u003eISO 6976\u003c\/strong\u003e calculations for natural gas. For cryogenic LNG, verify specific fluid property requirements against the module's supported equations of state.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I run multiple meter types simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, each of the \u003cstrong\u003e8 runs\u003c\/strong\u003e can be configured independently with different meter types and calculation standards.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your calculation standard requirements (AGA-3 vs ISO 5167) before configuration\u003c\/li\u003e\n\u003cli\u003eEnsure your ControlLogix analog input modules support the required transmitter resolution (typically 16-bit)\u003c\/li\u003e\n\u003cli\u003eFor multi-run applications, plan tag memory carefully — each run generates multiple status and totalizer tags\u003c\/li\u003e\n\u003cli\u003eConsider redundant transmitter configurations for custody transfer applications per API guidelines\u003c\/li\u003e\n\u003cli\u003eOrder the XT variant for outdoor installations or corrosive environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776371876024,"sku":"MVI56-AFC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-DFCM_r180.png?v=1784182867","url":"https:\/\/www.globalpetroparts.com\/products\/prosoft-mvi56-afc-advanced-flow-computer-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}