{"product_id":"prosoft-mvi56e-mnet-controllogix-modbus-tcp-ip-interface-module","title":"ProSoft MVI56E-MNET ControlLogix Modbus TCP\/IP Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a powerful Modbus TCP\/IP communication bridge within the Allen-Bradley ControlLogix platform. It enables ControlLogix processors to interface seamlessly with Modbus TCP\/IP-compatible devices, such as power meters, VFDs, and programmable controllers. By operating as both a Client and a Server, this module centralizes data collection and command distribution across industrial Ethernet networks. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory equipment\u003c\/strong\u003e, ensuring your automation architecture maintains peak data integrity and compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E-MNET utilizes the ControlLogix backplane for power while providing dedicated RJ45 ports for high-speed network traffic.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology (for Allen-Bradley Systems)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP (Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5V DC; 3 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30G (Operating); 50G (Non-Operating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 to 140°F (0 to 60°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Character Scrolling LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLocal or Remote via Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Mode Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports simultaneous Client and Server applications. This allows a single ControlLogix chassis to pull data from field sensors while simultaneously acting as a data provider for an upper-level SCADA system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Remote Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers configure and diagnose the module directly through the dedicated Ethernet port. This eliminates the need for specialized serial cables or local physical access, drastically reducing maintenance time in large-scale facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Status Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated 4-character scrolling LED display provides immediate hardware and network status. Technicians identify IP address conflicts or communication errors at a glance without connecting a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for heavy industrial environments, the module withstands operating shocks up to 30G. This mechanical durability prevents signal loss or hardware failure in high-vibration applications like mining or heavy stamping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Backplane Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the ControlLogix backplane, the module achieves high-speed data transfers between the Modbus network and the PLC tags, ensuring minimal latency for time-critical control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this MVI56E-MNET unit a newer version of the MVI56-MNET?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"E\" stands for Enhanced. The MVI56E-MNET provides superior configuration options, an updated web server, and improved diagnostic tools compared to the legacy non-E version. It serves as a direct functional replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module draws all necessary power directly from the ControlLogix backplane. Ensure your chassis power supply has sufficient overhead for the 800 mA draw at 5V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software do I need to configure the Modbus registers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProSoft provides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft Configuration Builder (PCB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. This tool allows you to map Modbus registers to ControlLogix tags through a user-friendly interface via the Ethernet port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I swap this module while the PLC is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile ControlLogix supports RIUP (Removal and Insertion Under Power), we recommend stopping the specific communication tasks in the PLC code before swapping to prevent data corruption in the Modbus registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53442026111160,"sku":"MVI56-MNET","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-MNET1.jpg?v=1778140967","url":"https:\/\/www.globalpetroparts.com\/products\/prosoft-mvi56e-mnet-controllogix-modbus-tcp-ip-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}