{"product_id":"prosoft-mvi56e-mnetq-modbus-tcp-ip-client-communication-module","title":"ProSoft MVI56E-MNETQ Modbus TCP\/IP Client Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-MNETQ\u003c\/strong\u003e is a \u003cstrong\u003eModbus TCP\/IP Client Communication Module\u003c\/strong\u003e designed for \u003cstrong\u003ehigh-speed, quick-response applications\u003c\/strong\u003e in Rockwell Automation ControlLogix systems. It features \u003cstrong\u003eenhanced client performance\u003c\/strong\u003e with faster polling cycles and optimized command processing, making it ideal for time-critical Modbus TCP\/IP master applications. The MVI56E-MNETQ provides \u003cstrong\u003esingle Ethernet port\u003c\/strong\u003e Client (Master) functionality with up to 100 command queues.\u003c\/p\u003e\n\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Client Communication Module (Quick Response)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Modbus TCP\/IP Client (Master)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand Queues:\u003c\/strong\u003e Up to 100 commands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance:\u003c\/strong\u003e Enhanced polling speed for quick-response applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane:\u003c\/strong\u003e 1756 ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Software:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Response:\u003c\/strong\u003e Optimized for high-speed client polling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 Command Queues:\u003c\/strong\u003e Large command capacity for complex networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Polling Cycles:\u003c\/strong\u003e Reduced response time for time-critical applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Ethernet Port:\u003c\/strong\u003e Dedicated client operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControlLogix Integration:\u003c\/strong\u003e Seamless data mapping to processor tags\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed data acquisition systems\u003c\/li\u003e\n\u003cli\u003eTime-critical process control\u003c\/li\u003e\n\u003cli\u003eMotion control with Modbus TCP\/IP devices\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring applications\u003c\/li\u003e\n\u003cli\u003eFast-responding SCADA systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall in 1756 ControlLogix slot\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet cable to RJ45 port\u003c\/li\u003e\n\u003cli\u003eConfigure IP address and command queues via PCB\u003c\/li\u003e\n\u003cli\u003eSet up to 100 Modbus TCP\/IP server connections\u003c\/li\u003e\n\u003cli\u003eOptimize polling intervals for response time requirements\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MVI56E-MNETQ and MVI56E-MNETC?\u003c\/strong\u003e\u003cbr\u003eA: MNETQ is optimized for high-speed client polling; MNETC is standard Client\/Server.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many servers can it poll simultaneously?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Up to 100 command queues for multiple server connections.\u003c\/p\u003e\n\n\u003ch3\u003eModel Selection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMVI56E-MNETQ = \u003cstrong\u003eHigh-speed Modbus TCP\/IP Client\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFor standard Client\/Server, use MVI56E-MNETC\u003c\/li\u003e\n\u003cli\u003eFor remote rack optimization, use MVI56E-MNETR\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53800541094072,"sku":"MVI56E-MNETQ","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETQ_deb9d9ce-0936-4076-8d7d-faafa7718e1e.png?v=1784796172","url":"https:\/\/www.globalpetroparts.com\/products\/prosoft-mvi56e-mnetq-modbus-tcp-ip-client-communication-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}