{"product_id":"prosoft-mvi69-pdpmv1-profibus-dpv1-master-module","title":"Prosoft MVI69-PDPMV1 PROFIBUS DPV1 Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69-PDPMV1\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP-V1 Master\/Slave Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation CompactLogix\u003c\/strong\u003e platform. It installs directly into a 1769 CompactLogix rack, enabling CompactLogix controllers to communicate with up to \u003cstrong\u003e125 PROFIBUS DP slave devices\u003c\/strong\u003e at speeds up to \u003cstrong\u003e12 Mbps\u003c\/strong\u003e. Operating as an independent communication co-processor, it offloads PROFIBUS protocol handling from the CompactLogix CPU, ensuring deterministic real-time performance.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI69-PDPMV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP-V1 Master\/Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI69 InRAx for CompactLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Rockwell CompactLogix L2, L3 series; MicroLogix 1100\/1400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0 \/ DP-V1 Master \u0026amp; Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Slaves (Master Mode):\u003c\/strong\u003e 125 devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 9.6 kbps to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 9-pin D-Sub female (PROFIBUS DP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 500 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Buffer:\u003c\/strong\u003e Large read\/write data buffers for high-throughput applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Mode Operation:\u003c\/strong\u003e Configurable as either PROFIBUS DP Master or Slave for flexible network roles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent Processor:\u003c\/strong\u003e Onboard co-processor manages entire PROFIBUS protocol stack, offloading CompactLogix CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Data Mapping:\u003c\/strong\u003e PROFIBUS data mapped directly to CompactLogix tags via simple read\/write operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Communication:\u003c\/strong\u003e 12 Mbps maximum baud rate ensures real-time deterministic data exchange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP-V1 Acyclic:\u003c\/strong\u003e Supports parameter configuration and diagnostic data exchange with intelligent field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e No complex ladder logic required — data exchange via standard tag database\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompactLogix integration of Siemens drives, valves, and remote I\/O\u003c\/li\u003e\n\u003cli\u003ePackaging lines with PROFIBUS-enabled servo controllers\u003c\/li\u003e\n\u003cli\u003eAutomotive body shops with mixed Rockwell\/Siemens control architectures\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems with distributed PROFIBUS motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF CompactLogix rack power before module installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the MVI69-PDPMV1 into any available I\/O slot on the 1769 rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection:\u003c\/strong\u003e Connect the 9-pin D-Sub to the PROFIBUS network using shielded cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Switches:\u003c\/strong\u003e Set the PROFIBUS station address using the rotary switches on the module front\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module to your Studio 5000\/RSLogix 5000 project as a generic 1769 module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Use ProSoft Configuration Builder to define master\/slave mode, baud rate, and device configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTag Mapping:\u003c\/strong\u003e Map PROFIBUS I\/O data to CompactLogix controller tags for seamless program access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up, verify module status LEDs, and confirm data exchange with PROFIBUS devices\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the MVI69-PDPMV1 operate as both master and slave simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the module operates in either \u003cstrong\u003eMaster mode\u003c\/strong\u003e or \u003cstrong\u003eSlave mode\u003c\/strong\u003e per configuration. It cannot perform both roles simultaneously.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this compatible with ControlLogix 5580 (L8x) controllers?\u003c\/strong\u003e\u003cbr\u003e\nA: The MVI69-PDPMV1 is designed for \u003cstrong\u003eCompactLogix L2\/L3\u003c\/strong\u003e and \u003cstrong\u003eMicroLogix 1100\/1400\u003c\/strong\u003e. For ControlLogix 1756 chassis, use the \u003cstrong\u003eMVI56-PDPMV1\u003c\/strong\u003e instead.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many PROFIBUS devices can I connect?\u003c\/strong\u003e\u003cbr\u003e\nA: In Master mode, up to \u003cstrong\u003e125 PROFIBUS DP slaves\u003c\/strong\u003e can be managed, limited by network timing and data payload.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic tools are available?\u003c\/strong\u003e\u003cbr\u003e\nA: ProSoft Configuration Builder provides live list monitoring, device status, error counters, and packet capture for troubleshooting.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your CompactLogix CPU model is in the compatibility list (L2x, L3x series)\u003c\/li\u003e\n\u003cli\u003eEnsure your 1769 rack power supply can deliver 500 mA @ 5VDC for this module\u003c\/li\u003e\n\u003cli\u003eFor ControlLogix 1756 platforms, select MVI56-PDPMV1 instead of MVI69-PDPMV1\u003c\/li\u003e\n\u003cli\u003eUse PROFIBUS connectors with built-in termination switches for easier maintenance\u003c\/li\u003e\n\u003cli\u003ePlan GSD file management carefully — keep backups of all slave device GSD files\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53775958868152,"sku":"MVI69-PDPMV1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69L-MBS2.jpg?v=1773049004","url":"https:\/\/www.globalpetroparts.com\/products\/prosoft-mvi69-pdpmv1-profibus-dpv1-master-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}