{"product_id":"prosoft-plx31-eip-pnd-ethernet-ip-to-profinet-io-device-gateway","title":"Prosoft PLX31-EIP-PND EtherNet\/IP to PROFINET IO Device Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-PND\u003c\/strong\u003e is an \u003cstrong\u003eEtherNet\/IP to PROFINET Device Gateway\u003c\/strong\u003e that enables seamless bi-directional data exchange between \u003cstrong\u003eRockwell Automation EtherNet\/IP controllers\u003c\/strong\u003e and \u003cstrong\u003eSiemens PROFINET IO controllers\u003c\/strong\u003e. This compact single-port gateway transparently maps data between EtherNet\/IP assembly instances and PROFINET IO data records, allowing ControlLogix and CompactLogix systems to communicate with Siemens ET200 distributed I\/O, V90 servo drives, and other PROFINET devices without complex programming or protocol expertise.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX31-EIP-PND\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to PROFINET Device Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX30 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Role:\u003c\/strong\u003e Adapter (Server)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Role:\u003c\/strong\u003e Device (Slave)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer:\u003c\/strong\u003e Bi-directional, up to 1440 bytes per direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Protocol Bridge:\u003c\/strong\u003e No programming required — data maps directly between EtherNet\/IP and PROFINET\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Single-Port Design:\u003c\/strong\u003e Cost-effective solution for simple point-to-point or switched network integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Role Operation:\u003c\/strong\u003e Simultaneously presents EtherNet\/IP Adapter data and PROFINET Device data\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-MDIX:\u003c\/strong\u003e Automatic crossover detection eliminates special Ethernet cabling requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e Built-in HTTP server for real-time status monitoring and configuration backup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Option:\u003c\/strong\u003e XT variant available for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive assembly integrating Rockwell PLCs with Siemens ET200SP distributed I\/O\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; beverage packaging with Allen-Bradley controllers and Siemens V90 servo systems\u003c\/li\u003e\n\u003cli\u003ePharmaceutical batch processing requiring mixed-vendor control platform communication\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems with Siemens G120C drives on PROFINET and Rockwell scanners on EtherNet\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Secure the PLX31-EIP-PND to a 35 mm DIN rail in an IP20 control cabinet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) to the power connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Side:\u003c\/strong\u003e Connect the EtherNet\/IP RJ45 to your Rockwell network (Stratix switch recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Side:\u003c\/strong\u003e Connect the PROFINET RJ45 to your Siemens network (SCALANCE switch recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Configuration:\u003c\/strong\u003e Use PLX50 Configuration Utility to assign IP addresses to both network interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Define input\/output data blocks mapping EtherNet\/IP assembly to PROFINET slots\/subslots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the gateway as a generic EtherNet\/IP module in your ControlLogix project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTIA Portal:\u003c\/strong\u003e Import the GSDML file and add the gateway as a PROFINET device in your Siemens project\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PLX31-EIP-PND and PLX32-EIP-PND?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePLX31\u003c\/strong\u003e has \u003cstrong\u003esingle Ethernet ports\u003c\/strong\u003e for basic point-to-point or switched connections. The \u003cstrong\u003ePLX32\u003c\/strong\u003e has \u003cstrong\u003edual Ethernet ports with embedded switches\u003c\/strong\u003e on each side, supporting daisy-chain or ring topologies.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this gateway require programming in the PLC?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the gateway operates transparently. Once configured, data flows automatically between mapped memory areas without ladder logic.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this for safety-rated (PROFIsafe) communication?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the PLX31-EIP-PND does not support PROFIsafe or CIP Safety. It is designed for standard process data exchange only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is VLAN tagging supported?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the gateway supports \u003cstrong\u003eIEEE 802.1Q VLAN tagging\u003c\/strong\u003e for network segmentation and traffic prioritization.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose PLX31 for simple star or switched topologies; upgrade to PLX32 for daisy-chain or device-level ring (DLR)\u003c\/li\u003e\n\u003cli\u003eVerify your EtherNet\/IP scanner supports the gateway's assembly instance sizes\u003c\/li\u003e\n\u003cli\u003eEnsure your PROFINET controller (S7-1200\/1500, ET200) supports the GSDML file revision\u003c\/li\u003e\n\u003cli\u003eFor installations near welding or chemical processing, order the XT (extended temperature\/conformal coat) variant\u003c\/li\u003e\n\u003cli\u003ePlan data block sizes carefully — larger blocks consume more PLC memory but reduce communication overhead\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776595058872,"sku":"PLX31-EIP-PND","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBTCP1.jpg?v=1776674267","url":"https:\/\/www.globalpetroparts.com\/products\/prosoft-plx31-eip-pnd-ethernet-ip-to-profinet-io-device-gateway","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}