{"product_id":"prosoft-technology-ilx56-pbm-controllogix-profibus-dpv1-master-slave-network-module","title":"ProSoft Technology ILX56-PBM ControlLogix PROFIBUS DPV1 Master \/ Slave Network Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft Technology ILX56-PBM functions as a high-capacity PROFIBUS DPV1 Master\/Slave communication module designed for seamless slot integration into Allen-Bradley ControlLogix backplanes. This intelligent gateway module interfaces ControlLogix Programmable Automation Controllers (PACs) with decentralized PROFIBUS field devices, including variable speed drives, motor starters, instrument transmitters, and remote I\/O blocks. We distribute this network interface module exclusively in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure clean backplane pin contacts, native firmware validation, and immediate high-speed data mapping without field data corruption.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology (Rockwell Automation Partner)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eILX56-PBM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DPV0 \/ DPV1 (Master or Slave Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Data Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5000 Bytes Total Input\/Output Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw (24V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Enclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Slot Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOccupies 1 Standard ControlLogix Chassis Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Category Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLCs \/ Machine Control Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Category Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC Communication Module \/ Rack Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs (0.91 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHandles Massive Data Payloads Across Fields:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module architecture processes up to 5000 bytes of cyclic and acyclic parameter data simultaneously. This large memory capacity enables system integrators to aggregate tracking data from multiple dense instrumentation clusters into a single ControlLogix chassis slot, reducing hardware module expenses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProvides Dual Master or Slave Mode Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis single hardware platform acts as either a PROFIBUS Master controlling remote plant sub-networks or as a downstream Slave reporting up to a larger Distributed Control System (DCS). This firmware flexibility simplifies spare parts inventory by consolidating two distinct network functions into one stock component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinisters Safe Maintenance with IP20 Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module faceplate and housing utilize a solid IP20 touch-safe design. This protective layout prevents maintenance technicians from making accidental finger contact with hot electrical terminals during routine system adjustments or adjacent wire routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlines Controller Memory Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module downloads cyclic PROFIBUS data profiles directly into user-defined data tags inside the host ControlLogix processor. This automatic internal tag generation bypasses complex ladder logic configuration routines and shortens commissioning time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run this module as a PROFIBUS DPV1 Master and a DPV0 Slave simultaneously on the same port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. You must configure the physical serial interface port to operate in one specific mode at a time (either as a Master node governing the line or as a single Slave station) within your ProSoft Configuration Builder software settings before linking the module to the active network trunk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this ProSoft communications module an authentic factory-new piece or a refurbished card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product is 100% brand new, authentic, and completely unused factory-original stock. It arrives inside its native manufacturer box with untouched static shielding wrap, factory validation inspection stamps, and pristine edge connectors completely intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation guidelines protect the module from picking up network grounding noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the 2.00 lbs module firmly into the standard 1756 chassis slot until the plastic top and bottom locking tabs click into position. Ensure your 1756 power supply module grounds cleanly to the main enclosure backplate, and connect the PROFIBUS network cable shield securely to the DB9 connector frame to drain away high-frequency electrostatic distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53478728958136,"sku":"ILX56-PBM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/ILX56-PBM.jpg?v=1779098111","url":"https:\/\/www.globalpetroparts.com\/products\/prosoft-technology-ilx56-pbm-controllogix-profibus-dpv1-master-slave-network-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}