{"product_id":"ptq-pdpmv1-prosoft-rockwell-communication-interface-module","title":"PTQ-PDPMV1 | Prosoft | Rockwell Communication Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PTQ-PDPMV1\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP-V1 Master Network Interface Module\u003c\/strong\u003e designed for \u003cstrong\u003eSchneider Electric Quantum and Unity\u003c\/strong\u003e processor platforms. It enables Quantum PLCs to act as PROFIBUS DP masters, controlling up to \u003cstrong\u003e125 slave devices\u003c\/strong\u003e at speeds up to \u003cstrong\u003e12 Mbps\u003c\/strong\u003e. With support for both DPV0 cyclic data exchange and DPV1 acyclic parameter access, this module provides comprehensive integration of PROFIBUS devices into Modicon control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PTQ-PDPMV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP-V1 Master Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft InRAx for Quantum\/Unity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0 \/ DP-V1 Master\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Slaves:\u003c\/strong\u003e Up to 125 PROFIBUS DP devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 9.6 kbps to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane:\u003c\/strong\u003e Single-slot Quantum backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB) with GSD file import\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDPV1 Services:\u003c\/strong\u003e Class 1 and Class 2 acyclic read\/write\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Extended diagnostic data, alarm handling, live list monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports hot standby configurations (up to 4 modules per rack)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware:\u003c\/strong\u003e Flash-upgradable in the field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull DPV1 Master:\u003c\/strong\u003e Supports both cyclic I\/O and acyclic parameter data exchange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Device Count:\u003c\/strong\u003e Manages up to 125 PROFIBUS slaves from a single Quantum rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated GSD Parser:\u003c\/strong\u003e Automatically configures slave devices from manufacturer GSD files\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Standby Support:\u003c\/strong\u003e Enables redundant PROFIBUS master configurations for critical applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Live list, device status, and alarm monitoring via PCB software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnity Pro Compatible:\u003c\/strong\u003e Seamlessly integrates with Schneider Unity Pro programming environment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation turbine control with distributed I\/O\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas pipeline SCADA with PROFIBUS field instruments\u003c\/li\u003e\n\u003cli\u003eWater treatment plant integration of Siemens drives and sensors\u003c\/li\u003e\n\u003cli\u003eChemical processing with multi-vendor device networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the Quantum rack before module insertion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Install the PTQ-PDPMV1 in any available I\/O slot on the Quantum backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Wiring:\u003c\/strong\u003e Connect the 9-pin D-Sub connector to the PROFIBUS network bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Install termination resistors at both physical ends of the PROFIBUS segment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSD Import:\u003c\/strong\u003e Import slave device GSD files into ProSoft Configuration Builder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e Define slave addresses, I\/O mapping, and DPV1 parameters in PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnity Pro Integration:\u003c\/strong\u003e Add the module to your Unity Pro project and map I\/O variables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e If using hot standby, configure primary and backup modules per ProSoft guidelines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up, verify live list, and confirm cyclic data exchange with all slaves\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PTQ-PDPMV1 and MVI69-PDPMV1?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePTQ-PDPMV1\u003c\/strong\u003e is for \u003cstrong\u003eSchneider Quantum\/Unity\u003c\/strong\u003e platforms, while the \u003cstrong\u003eMVI69-PDPMV1\u003c\/strong\u003e is for \u003cstrong\u003eRockwell CompactLogix\u003c\/strong\u003e. Both offer identical PROFIBUS DP-V1 master functionality on different PLC platforms.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module in a Quantum Hot Standby system?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the PTQ-PDPMV1 supports \u003cstrong\u003ehot standby redundancy\u003c\/strong\u003e configurations with up to 4 modules per rack for enhanced reliability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What cable type is recommended?\u003c\/strong\u003e\u003cbr\u003e\nA: Use \u003cstrong\u003ePROFIBUS Type A shielded twisted-pair cable\u003c\/strong\u003e (purple) for standard installations. Type B is acceptable for shorter runs at lower baud rates.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support PROFINET?\u003c\/strong\u003e\u003cbr\u003e\nA: No, this is a \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e master only. For PROFINET integration, consider ProSoft PLX31-EIP-PND or PLX32-EIP-PND gateways.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your Quantum CPU firmware supports ProSoft communication modules\u003c\/li\u003e\n\u003cli\u003eCalculate total PROFIBUS cable length and ensure it meets baud rate specifications\u003c\/li\u003e\n\u003cli\u003eStock spare GSD files from all slave device manufacturers for quick replacement\u003c\/li\u003e\n\u003cli\u003eFor networks exceeding 32 devices or long cable runs, plan for PROFIBUS repeaters\u003c\/li\u003e\n\u003cli\u003eConsider conformal-coated variant for installations in corrosive atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53775958212792,"sku":"PTQ-PDPMV1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-ADM.png?v=1784182868","url":"https:\/\/www.globalpetroparts.com\/products\/ptq-pdpmv1-prosoft-rockwell-communication-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}