{"product_id":"pw301-yokogawa-power-supply-module-power-quality-monitoring","title":"PW301 | Yokogawa | Power Supply Module | Power Quality Monitoring","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa PW301\u003c\/strong\u003e Power Supply Module is part of Yokogawa’s advanced power quality monitoring suite, designed to deliver precise measurement and analysis of electrical parameters. This module supports comprehensive monitoring of voltage, current, and frequency, while offering long-term data logging and transient waveform capture for detailed diagnostics. With integrated communication protocols and real-time display, the PW301 ensures reliable performance in both industrial and commercial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e: Voltage up to 1000 V AC, current up to 600 A AC (via CT).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Monitoring\u003c\/strong\u003e: Operates across 45–65 Hz range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e: Long-term storage capability plus transient waveform capture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e: RS-232, Ethernet, Modbus, and additional protocols for remote monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Display\u003c\/strong\u003e: LCD screen for immediate visualization of power parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Reliability\u003c\/strong\u003e: Operates from -10°C to +50°C, humidity tolerance up to 90% non-condensing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePW301\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module \/ Power Quality Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 600 A AC (with CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003eLong-term storage, transient waveform capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, Ethernet, Modbus, others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD for real-time monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0–90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Facilities\u003c\/strong\u003e: Continuous monitoring of electrical systems for stability and efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommercial Buildings\u003c\/strong\u003e: Power quality analysis to ensure compliance and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUtility Systems\u003c\/strong\u003e: Long-term logging for diagnostics and predictive maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum voltage the PW301 can measure?\u003c\/strong\u003e  A: It supports measurement up to 1000 V AC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it log data for extended periods?\u003c\/strong\u003e  A: Yes, it supports long-term data storage for several months.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does it allow remote monitoring?\u003c\/strong\u003e  A: Yes, via Ethernet, RS-232, Modbus, and other supported protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is transient analysis supported?\u003c\/strong\u003e  A: Yes, waveform snapshots can be captured for transient event analysis.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022184898744,"sku":"PW301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PW301.jpg?v=1773739185","url":"https:\/\/www.globalpetroparts.com\/products\/pw301-yokogawa-power-supply-module-power-quality-monitoring","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}